EZSTLDWS*1G EZSTL8WS*1G, 2G, 3G LZSTLDWS*1G LZSTL8WS*1G, 2G, 3G
Page 61000002243 (Rev. H - 01/21)
EZSTLDWS*1G EZSTL8WS*1G, 2G, 3G LZSTLDWS*1G LZSTL8WS*1G, 2G, 3G
Page 61000002243 (Rev. F - 07/19)
17 7/8"
454mm
7"
178mm
7"
178mm
7/16" X 3/4"
11mm X 19mm
OBROUND HOLES
(6)
15"
381mm
2 7/8"
73mm
2"
51mm
57 1/16"
1450mm
34 5/16"
872mm
24 1/2"
622mm
22 15/16"
583mm
19 7/16"
494mm
21 7/8"
556mm
19"
483mm
28 13/16"
732mm
2"
51mm
17 7/16"
443mm
13 15/16"
354mm
7"
178mm
7"
178mm
5 3/4"
146mm
2"
51mm
FINISHED FLOOR
18 3/8"
467mm
6 3/8"
162mm
6 3/8"
162mm
6 3/8"
162mm
6 3/8"
162mm
2"
51mm
7/8"
22mm
E
E
A
(ALT. LOCATION)
F
D
PREFERRED
LOCATION
D
(ALT. LOCATION)
9/32" Ø
7mm Ø
HOLES
12
B
A
PREFERRED
LOCATION
12 1/2"
318mm
3"
77mm
1 7/16"
37mm
C
8 1/16"
205mm
18 7/8"
479mm
3 9/16"
90mm
19"
483mm
HANGER BRACKET
38 3/8"
975mm
ORIFICE
HEIGHT
36 13/16"
935mm
RIM
HEIGHT
32 7/8"
835mm
ORIFICE
HEIGHT
31 5/16"
796mm
RIM
HEIGHT
FILTER
FILTER
27"
686mm
ADA
REQUIREMENT
F
3 7/8"
98mm
ACTIVATION
SENSOR
44"
1118mm
LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY OTHERS) 3 IN. (76mm)
MAXIMUM OUT FROM WALL
/D8%,&$&,2125(&20(1'$'$GH$%$67(&,0,(172'($*8$'(O78%2GHO&2%5(GH813/$7('&21(&7$7$/21$5,2&21$3$*2
32527526HQ0PHO0$;,02)8(5$'(3$5('
/¶2'GHG¶(03/$&(0(17'(3529,6,21'¶($85(&200$1'(/(78%('(&8,95('(813/$7('&211(&7(678%$9(&(7(,173$5
/(6$875(6GDQVPPOH0$;,080+256'8085
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2 O.D. DRAIN STUB 2 IN. OUT FROM WALL
8%,&$&,Ï15(&20(1'$'$3$5$(/'5(1$-('(6$/,'$'($*8$'(´'(',È0(752El TALONARIO 2 FUERA DE PARED
(03/$&(0(175(&200$1'e3285/('5$,1'('(´'(6257,('¶($8STUB 2 HORS DU MUR
C = 1-1/2 TRAP NOT FURNISHED
385*$'25'(´12352325&,21$'2
6,3+21´121)2851,
LEGEND/LEYENDA/LÉGENDE
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX DUPLEX OUTLET**
680,1,6752(/e&75,&2&$-$(1&+8)('($/$0%5(6$/,'$'Ò3/(;
ALIMENTATION ÉLECTRIQUE (3) BOÎTIER ENCASTRÉ
E = INSURE PROPER VENTILATION BY MAINTAINING 6 (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
$6(*85(81$9(17,/$&,Ï1$'(&8$'$0$17(1,(1'281(63$&,2(´PP0Ë1'(+2/*85$(175(/$5(-,//$
'(9(17,/$&,Ï1'(/08(%/(</$3$5('
$6685(=928681(%211(9(17,/$7,21(1*$5'$17´PP0,1(175(/(6e9(176'(/(1&(,17((7/(085
F = 7/16 BOLT HOLES FOR FASTENING UNIT TO WALL
AGUJEROS DE LAS TUERCAS DE 7/16 PARA SUJETAR LA UNIDAD A LA PARED
75286'e&52863285),;(5/$33$5(,/$8085
**NEW INSTALLATIONS MUST USE GROUND FAULT CIRCUIT INTERRUPTER (GFCI)
**Las nuevas instalaciones deben utilizar el interruptor de circuito de tierra de la avería (GFCI)
**Les nouvelles installations doivent employer l’interrupteur de circuit moulu de défaut (GFCI)
REFRIGERATED UNIT MUST BE INSTALLED ON RIGHT-HAND SIDE.
REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDREN’S ADA COOLER
ALTERNATE ROUGH-IN FOR LEFT-HAND HIGH, BOTTLE FILLER HIGH MODELS
Fig. 5
REQUIRES BASIN ASSY CHANGE. SEE PAGES 11-13 FOR INSTRUCTIONS
REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDREN’S ADA COOLER
ALTERNATE ROUGH-IN FOR LEFT-HAND HIGH, BOTTLE FILLER HIGH MODELS
Fig. 5
REQUIRES BASIN ASSY CHANGE. SEE PAGES 11-13 FOR INSTRUCTIONS
LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY OTHERS) 3 IN.
(76mm) MAXIMUM OUT FROM WALL
La UBICACION 3/8 O RECOMENDADA de ABASTECIMIENTO DE AGUA. D. El TUBO del COBRE de UNPLATED CONECTA TALONARIO CON APAGO
(POR OTROS) 3 en. (76 Mm) el MAXIMO FUERA DE PARED
L’O.D de 3/8 d’EMPLACEMENT DE PROVISION D’EAU RECOMMANDE. LE TUBE DE CUIVRE DE UNPLATED CONNECTE STUB AVEC ETEINT (PAR
LES AUTRES) 3 dans. (76 mm) le MAXIMUM HORS DU MUR
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2” O.D. DRAIN STUB 2 IN. OUT FROM WALL
UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1-1/2” DE DIÁMETRO. El TALONARIO 2 FUERA DE PARED
EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/2” DE SORTIE D’EAU. STUB 2 HORS DU MUR
C = 1-1/2” TRAP NOT FURNISHED
PURGADOR DE 1-1/2” NO PROPORCIONADO
SIPHON 1-1/2” NON FOURNI
NOTE: IT IS HIGHLY RECOMMENDED THAT THE CIRCUIT BE DEDICATED AND THE LOAD PROTECTION BE SIZED FOR 20 AMPS.
LEGEND/LEYENDA/LÉGENDE
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX DUPLEX OUTLET**
SUMINISTRO ELÉCTRICO (3) CAJA ENCHUFE DE ALAMBRE SALIDA DÚPLEX
ALIMENTATION ÉLECTRIQUE (3) BOÎTIER ENCASTRÉ
E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 6” (152 mm) (MÍN.) DE HOLGURA ENTRE LA REJILLA
DE VENTILACIÓN DEL MUEBLE Y LA PARED.
ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 6” (152 mm) (MIN.) ENTRE LES ÉVENTS DE L’ENCEINTE ET LE MUR.
F = 7/16 BOLT HOLES FOR FASTENING UNIT TO WALL
AGUJEROS DE LAS TUERCAS DE 7/16 PARA SUJETAR LA UNIDAD A LA PARED
TROUS D’ÉCROUS 7/16 POUR FIXER L’APPAREIL AU MUR
**NEW INSTALLATIONS MUST USE GROUND FAULT CIRCUIT INTERRUPTER (GFCI)
**Las nuevas instalaciones deben utilizar el interruptor de circuito de tierra de la avería (GFCI)
**Les nouvelles installations doivent employer l’interrupteur de circuit moulu de défaut (GFCI)
REFRIGERATED UNIT MUST BE INSTALLED ON RIGHT-HAND SIDE.