for use with Natural gas/ULPG (supplied with the Natural gas/ULPG conversion kit).
A second Natural gas/ULPG conversion label should also be a󰀩xed to an adjacent
surface along with the duplicate data plate.
Adjusting the minimum burner setting
Follow the instructions under ‘MINIMUM BURNER SETTING ADJUSTMENT’ following.
IMPORTANT
If the cooktop is suitable for use with Natural gas and must be converted for use with
Universal LPG, before connecting to gas main remove the appliance gas regulator and
replace with test point adaptor (see gs. 4a, 4b).
If the cooktop is suitable for use with Universal LPG and must be converted for use
with Natural gas, before connecting to the gas main remove the appliance test point
adaptor and replace with gas regulator (see gs. 4a, 4b).
NOTE:
Gas regulator and test point adaptor are supplied with the appliance (packed with
conversion kit).
The burners are designed so that regulation of primary air is not required.