Performance Data Sheet
Models Number ADQ72910902
Use with replacement cartridge ADQ72910902
This system has been tested according to NSF/ANSI 42 for the reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42.
I System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction
I
of Chlorine, Taste and Odor and Nominal Particulate Class Ill.
Substance Average Influent Challenge Avg. Product Average Max. Min. Required
Water % Effluent
Influent Concentration Reduction
Concentration Reduction Mg/L
Particulate Class III 48,000 At least 10,000 particles/mL 7.5 99.9 % 26 > 85%
Particles 5 um to 15 um
Chlorine taste and odor 2.0 mg/L 2.0 mg/L + 10% mg/L 97.4 % 0.06 mg/L _> 50%
* To a capacity of 500gallons. (1,892 Liters)
* Notethat while the testing was performed under standard laboratory conditions, actualperformance may vary.
Application Guidelines / Water Supply Parameters
Service flow 0.5 gpm (1.9 Ipm)
Water pressure 20 - 125 psi (138- 862 kPa)
Water temperature 34 °F - 100 °F (1 - 38 °C )
BWARNING
Toreduce the risk associated with ingestion of contaminants due to use
with water that is microbiologically unsafe or of unknown quality.
Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
Systemsmustbeinstalledandoperatedinaccordancewith manufacturer's
recommendedproceduresandguidelines,
Warranty:SeeWarrantyCardfor Details.
E_CAUTION
To reduce the risk of property damage due to water leakage:
_ Read and follow Use instructions before installation and use of this system.
_) Install on COLD water lines only.
(._ Company with all state and local plumbing codes,
(o_ Install a pressure limiting device and water hammer arrester for inlet water pressures
exceeding 80 psi (SS2kPa). Refer to Uniform Plumbing Code, Sections 608.2 and 609.10.
_) Never install or operate where inlet water pressure may exceed 125 psi (862kPa).
_ Protect filter from freezing. Remove filter in temperatures below 34°F (1°C).
_) Replace cartridge at specified service interval. Cartridge MUST be replaced at least
every 6 months.
(i) After replacing the water filter cartridge, dispense water dispenser for S minutes or
2.5 Gallons to purge water system. Discard the purged water.
Topurchaseareplacementfilter,visityourlocalSearsstoreor call1-800-4-MYHOME®.
Visitusonthewebatwww.sears.com
Distributedby:
SearsBrand ManagementCorporation
3333BeverlyRoad
HoffmanEstates,IL60179
25