Rinnai EHF250S36 250L Electric Hot Water System

Installation Manual - Page 12

For EHF250S36. Series: HOTFLO (EHFA/EHFD)

PDF File Manual, 20 pages, Read Online | Download pdf file

EHF250S36 photo
Loading ...
Loading ...
Loading ...
Rinnai 12 EHFA/EHFD HW IM
HOT WATER PLUMBING SYSTEM EXAMPLE - NO TLD
*PTR VALVE
(Supplied)
KITCHEN
LAUNDRY
NON TEMPERED SUPPLY
BATHROOM
ENSUITE
TO DRAIN
COLD
SUPPLY
Isolating
Valve
*ECV
TO DRAIN
Non-return
Valve
*PLV
WATER
HEATER
(Not Supplied)
CAUTION
ValveswithpressureratingsotherthanspeciedareunsuitableandMUST NOT beused.
*
Forratingssee"Table2.Ratings&OtherSpecications"onpage11.
HOT WATER PLUMBING SYSTEM EXAMPLE - WITH TLD
KITCHEN
LAUNDRY
ENSUITE
BATHROOM
TEMPERED
SUPPLY Temperature
Limiting Device
(TLD)
COLD
SUPPLY
Non-return
Valve
*PLV
Isolating
Valve
Isolating
Valve
*PLV
*ECV
(OR)
WATER
HEATER
Non-return Valve
COLD
SUPPLY
Non-return
Valve
Non-return
Valve
WATER
HEATER
Temperature
Limiting Device
(TLD)
Non-return
Valve
*PTR VALVE
(Supplied)
TO DRAIN
*ECV
TO DRAIN
TO DRAIN
(Not Supplied)
TEMPERED
SUPPLY
*PLV
NON TEMPERED SUPPLY
NON TEMPERED SUPPLY
Isolating
Valve
Non-return
Valve
CAUTION
ValveswithpressureratingsotherthanspeciedareunsuitableandMUST NOT beused.
*
Forratingssee"Table2.Ratings&OtherSpecications"onpage11.
It may be a requirement that the hot and cold water supply pressures to a Temperature Limiting Device (TLD) are
equal� If this is the case, a PLV with the same pressure rating as the PLV for the hot water is required for the TLD
as shown�
INSTALLATION METHODS