Adjustment To Different Gas Types
To perform the adjustments to different types of gas, the qualied
installer shall follow the instructions given on this section.
Natural Gas
Make sure that the Natural Gas regulator supplied with the appliance is
installed and, with the triple ring burner operating at its maximum, adjust
the test point pressure to 1.00 kPa.
Universal ULPG
To convert from Natural Gas to Universal LPG, ensure that the Natural
Gas regulator is replaced by the Test Point Assembly supplied with the
appliance. Adjust the test point pressure to 2.75 kPa.
To adapt the appliance to a gas different from that for which it was set
up proceed as follows:
1. Remove the trivets
2. Remove the burners caps and diffusers
3. With a 7 mm socket spanner unscrew and remove the injectors.
4. Replace the injectors with those supplied corresponding to the gas
available (see burner and injector characteristics table)
5. Replace the various parts proceeding in reverse.
Figure 1 Figure 2