9
WARNING
Never attempt to attach this grill to the self-contained LP gas system. Do not use grill until leak testing.
Before Testing
DO NOT smoke while leak testing. Extinguish all open flames. Never leak test with an open flame. Mix
a solution of equal parts mild detergent or liquid soap and water.
Leak Testing Valves, Hose and Regulator
1. Turn all grill control knobs to OFF.
2. Be sure hose is tightly connected to LP tank.
3. Completely open LP tank valve by turning cylinder
valve knob counterclockwise (right to left). If you hear
a rushing sound, turn gas off immediately. There is a
major leak at the connection. Correct before
proceeding by calling franchiser for replacement
parts.
4. Brush soapy solution onto areas where bubbles
are shown in LP tank (see picture).
5. If “growing” bubbles appear, there is a leak. Close
LP tank valve immediately and retighten connections.
If leads cannot be stopped do not try to repair. Call franchiser for replacement.
6. Always close LP tank valve after performing leak test by turning cylinder valve knob clockwise.
NOTE:
When leak testing this appliance, make sure to test and tighten all loose connections, including
the side burner. A slight leak in the system can result in a low flame, or a hazardous condition.
LP Gas Supply Cylinder Disconnection
1. Turn the burner valves off.
2. Turn the tank valve off. (Turn clockwise to stop).
3. Detach the regulator assembly from the tank valve by turning the quick coupling nut
counterclockwise.
LP Tank Removal, Transport and Storage
- Turn OFF all control knobs and LP tank valve. Turn coupling
nut counterclockwise by hand only - do not use tools to
disconnect. Lift LP tank wire upward off of LP tank collar, then
lift LP tank up and off of support bracket. Install safety cap onto
LP tank valve. Always use cap and strap supplied with valve.
Failure to use safety cap as directed may result in serious
personal injury and/or property damage.