6. Error Codes
The error codes are depicted by a number of flashes by the error light in a sequence every
four seconds.
Code Reason / Solution
ERR1 or ERR2
(On Display
instead on
temperature)
Faulty temperature probe
Please call Evakool for closest service centre.
1 Flash
Low Voltage
Please check the source voltage to ensure it is above the cut out. Try
lowering the voltage cut out setting to LO.
The vehicle cabling may be inadequate/unsuitable, please refer to
cable specifications table for correct cable thickness (page 5).
Try on a dierent power source.
2 Flashes
Fan or compressor running issue
Fan is drawing too many Amps (Over 1 Amp) –Replace Fan.
The compressor is drawing too many amps (Over 12 Amps).
Possible Electronic Box or compressor fault – contact Evakool or
Service Agent.
3 Flashes
The compressor speed is too low
Reduce products / items inside unit.
Move unit to a lower ambient temperature.
Clean vents / ensure clear air flow over compressor.
4 Flashes
Ambient Temperature too high
Clean vents / ensure clear air flow.
Fan Fault – Replace fan.
5 Flashes
Thermal Cut-Out of Electronic Unit
If the refrigeration system has been too heavily overloaded.
Ambient temperature is too high.