4 49-5000041 Rev. 6
USING THE AIR CONDITIONER
Controls
ŶPOWER
3UHVVWKH32:(5EXWWRQWRWXUQWKHXQLWRQRURII
:KHQWKHXQLWLVRQWKHSRZHULQGLFDWRUOLJKWZLOOEH
JUHHQ:KHQWKHXQLWLVRIIWKHOLJKWZLOOJRRXW
ŶMODE
3XVKWKLVEXWWRQWRF\FOHWKURXJKWKHPRGHVIURP
&22/+($7)$1&22/7KHLQGLFDWRUOLJKWEHVLGH
WKH³02'(´RSWLRQZLOOLOOXPLQDWHLGHQWLI\LQJWKHPRGH
selected.
COOL: The range of set temperature is 62°F~86°F.
Cooling begins automatically when the room
temperature is above the set point,and stops when the
room temperature is 4°F below the set point. But the
FRPSUHVVRUZLOOUXQDPLQLPXPRIPLQXWHVLQ&22/
mode before stopping. The fan is set up from the
factory to run in continuous mode when in cooling.
HEAT: The range of set temperature is 62°F~84°F.
For heat pump models the unit can alternate running
between reverse cycle heat mode and electric heater
mode according to the difference between the set
temperature and the room temperature. The fan motor
cycles on and off with the compressor and electric
heater.
The indoor fan motors starts before the compressor
and stops after the compressor cycles off.
NOTE: Reverse cycle heating and electric heater
cannot be run at the same time. In the following cases,
it is normal that the compressor does not operate.
:KHQWKHRXWGRRUWHPSHUDWXUHLVORZHUWKDQ)RU
the room temperature falls to 8°F below the set point
temperature.
7RSUHYHQWVKRUWF\FOLQJWKHUHLVDPLQXWH
PLQLPXPFRPSUHVVRU2))WLPHEHWZHHQF\FOHV
:KHQIURVWEXLOGVXSWRWKHHYDSRUDWRUFRLOVWKHXQLW
will defrost automatically and the compressor will
cycle off.
• FAN: Fan operation only without heating and cooling.
NOTE: The set temperature ranges can be changed.
6HH³',36:,7&+(6&21),*85$7,216RQSDJH 6
for details.
ŶUP/DOWN BUTTONS ( + / - )
3XVKWKH83RU'2:1EXWWRQWRLQFUHDVHRU
decrease) the set temperature of the unit in cooling
or heating mode. The temperature can be set by
LQFUHPHQWVRI)7KHVHWWHPSHUDWXUHDSSHDUVLQWKH
display.
NOTE: 3UHVVDQGKROGDQGEXWWRQVWRJHWKHUIRU
seconds will alternate the temperature display between
°C & °F scale.
ŶFAN (FAN SPEED)
(YHU\WLPH\RXSXVKWKLVEXWWRQWKHIDQVSHHGF\FOHV
WKURXJKWKHVHWWLQJVDVIROORZV+,*+0('/2:
Ŷ&2167$17)$1
3URYLGHVFKRLFHRIRSHUDWLQJWKHLQGRRUIDQ
continuously or cycling it on/off with the compressor.
$IDQLFRQDSSHDUVQHDUWKHGLVSOD\ZKHQWKHIDQLV
LQFRQVWDQWPRGH:KHQLQF\FOHPRGHWKHIDQZLOO
operate for several seconds after the compressor
F\FOHVRII7KLVVZLWFKLVQRWDFWLYHLQWKH+HDWPRGH
Ŷ',63/$<6
:KLOHRQ)DQRQO\PRGHLWVKRZVWKHURRP
temperature.
Control code (on some models):
LC 3XVKEXWWRQVRQWKHFRQWUROSDQHODUHQRW
available. The unit can only be operated by using wall
thermostat.
FC 3XVKEXWWRQVRQWKHFRQWUROSDQHODQGZDOO
thermostat are not available. The unit can only be
RSHUDWHGE\XVLQJ)5217'(6.&21752/
Error codes:
AS5RRPWHPSHUDWXUHVHQVRUHUURU
ES(YDSRUDWRUWHPSHUDWXUHVHQVRUHUURU
CS&RQGHQVHUWHPSHUDWXUHVHQVRUHUURU
OS2XWVLGHWHPSHUDWXUHVHQVRUHUURU
HS([KDXVWWHPSHUDWXUHVHQVRUHUURU
LE:LUHFRQWUROOHUHUURU
NOTE: :KHQHUURURFFXUVXQSOXJWKHXQLWDQGSOXJLW
back in.If error repeats, call for service.
2WKHUFRGHV
LO5RRPWHPSHUDWXUHLVORZHUWKDQ)
HI5RRPWHPSHUDWXUHLVKLJKHUWKDQ)
FP/RZWHPSHUDWXUHSURWHFWLRQ
NOTE:$OOWKHLOOXVWUDWLRQVLQWKLVPDQXDODUHIRU
H[SODQDWLRQSXUSRVHVRQO\<RXUDLUFRQGLWLRQHUPD\EH
slightly different.
NOTE: This air conditioner is designed to be operated
under the conditions listed above.
NOTE:3HUIRUPDQFHPD\EHUHGXFHGLIRXWVLGHWKHVH
operating temperatures.
Air Conditioner Controls
&RROLQJ2SHUDWLRQ
2XWGRRU7HPS °F
,QGRRU7HPS °F
+HDWLQJ2SHUDWLRQ
2XWGRRU7HPS °F
,QGRRU7HPS °F