TUMBLE DRYER
Step 1
Open the door of your dryer
Step 2
Pull out the fi lter (using the
two fi nger grips)
Step 3
Clean the fl uff off the fi lter
and replace it correctly.
Ensure that the fi lter is
pushed fully home.
Step 4
Make sure the fi lter is pushed fully home
NEVER run the dryer without the fi lter in position
Failure to clean the fi lter after EVERY drying
cycle will affect the drying performance of your
machine. It will take longer to dry and as a result
will use more electricity during drying.
At least every two or three months you MUST
clean fl uff build up around the fi lter housing and
the vent tube.
IDV 75 UK
IDV 75 S UK
IDV 75B K UK
WHERE TO INSTALL THE TUMBLE DRYER
1
0
m
m
15 mm
15 mm
15 mm
15 mm
If you are going to install the
appliance under a work
counter be sure to leave a
10 mm space between the
top and any other objects on
or above the machine and a
15 mm space between the
sides and any kitchen units
or walls to ensure proper air circulation. The
dryer must never be installed behind a lockable
door, a sliding door or a door with a hinge on the
opposite side to that of the dryer door.
The appliance must be installed with the rear
surface placed against a wall.
VENTILATION
When the dryer is in use there has to be adequate
ventilation to avoid the back fl ow of gases into
the room from appliances burning other fuels,
including open fi res. The vent tube should not exceed 2.4
metres in length. The tube should be kept clear of the air intake
vent and kinks or ‘U’ bends must be avoided as these will obstruct
the tube and trap condensation.
VENTING
Wall mounting
Keep the tube as short and as straight
as possible to prevent condensation
forming in the vent pipe.
The duct in the wall should slope
slightly downwards.
Window mounting
The hole in the window should be as
low down as possible and the tube should be kept as short as
possible.Depending on how often you use your tumble dryer, it is
essential that areas
A and B are checked periodically to remove
lint or debris.
This symbol reminds you to read this booklet.
B
A
Open window venting
The end of the tube should be
directed downwards, to prevent
warm moist air from condensing in
the room or dryer.
Do not discharge exhaust
air into a fl ue which is used
for exhaust fumes from
other appliances that burn gas or other fuels.
Do not discharge exhaust air into an extraction system or any duct
with an extractor fan. This will affect the way the thermal controls
operate and can result in a fi re hazard.
ELECTRICAL CONNECTIONS
The socket must be grounded. The power supply
cord should be checked periodically. If the
supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly
qualifi ed persons in order to avoid a hazar
LEVELLING YOUR DRYER
The dryer must be installed level for
correct operation. When you have
installed your dryer in its fi nal location
check that it is fi rst level side to side and
then back to front.
If the dryer is not level use a wooden
block to support it while adjusting the
two front legs up or down until your dryer is level.