2. Your Safety
This guide is for the installation of the motor used in the Isodrive systems after the canopy/rangehood or
bathroom extraction grill has been mounted on the wall or ceiling. (Refer to canopy/rangehood or bathroom
extraction unit installation manual).
NOTE: All PVC pipe and SteelFlex
ducting measurements are referring to inside measurements, unless
otherwise mentioned..
Motor Features
Roof and wall mounting with IPX4 degree of weather protection.
Patented anti water intrusion system.
Super quiet, long vane, backward curved centrifugal fan.
Airow is dependant on installation and the ducting used. Using a single 200mm SteelFlex
duct, you
should attain up to 900m
3
/hr depending on the ducting installation. The use of a smaller than 200mm
ducting would result in a loss of airow.
Simple installation: The motor mounts onto a 150mm PVC pipe for ultimate strength and allows for easy
Dektite roof sealing.
Industrial quality motor and fan made in Germany and rated at 40,000 hours.
Motor is a high eciency PSC type and rated at 57W.
WARRANTY 10 YEARS return to manufacturer. Covers faulty manufacturing or components. It does not
cover normal wear and tear, chemical or storm damage etc. (see warranty card for more information).
General Notes on Installation and Use
This fan unit is designed to be installed using 150mm (ISD) PVC pipe as the initial connection duct to the fan
module, and is supplied with a 150mm (ISD) PVC pipe to 200mm SteelFlex
duct bell-mouth adaptor.
This fan is suitable for connection to ducting runs with a minimum inlet area of 22,000mm
2
and length up to
8 metres maximum (check with supplier if longer duct length required). SteelFlex
ducting must be extended
suciently to present a smooth air passage with bends of at least the radius of twice the diameter of the duct.
Excessive bends in the ducting will compromised extraction.
WARNING: The rangehood must not be ducted into a wall cavity or a ceiling space, where a build up of grease
can occur and become a potential re risk. This will void your warranty.
NOTE: Fan module and Steelex
duct are acoustically matched. Use of semi-rigid or rigid ducting will result
in increased noise and may void warranty. See installation instruction notes ‘Why Schweigen SteelFlex
Safety Duct’.
Recommended Installation Distance
Isodrive 900 motor, recommended 4 metres of SteelFlex
ducting and with at least two bends.
NOTE: Installation closer than this distance may result in higher noise level. Maximum duct length is 8 metres.
Check with supplier if longer duct length is required. Do not reduce the duct size at any time and avoid
sharp bends.