Installation- continued
Electric connection
Cookers with a three-pole power supply cable are designed to operate with alternated current at the supply frequency and
voltage indicated on the data plate (at the bottom of the oven dashboard). The earthing conductor of the cable is the
yellow-green conductor.
Connecting the power supply cable to the mains
The appliance must be directly connected to the mains using an circuit-breaker with a minimum contact opening of 3 mm
installed between the appliance and the mains, suitable for the load indicated and complying with
current directives (the earthing wire must not be interrupted by the circuit-breaker).
The power supply cable must be positioned so that it does not exceed 50 more than room temperature at any point
of its length.
Before making the connections check that:
the household circuits can support the appliance load (see data plate);
the power supply system has an efficient earthing connection which complies with the provisions of current regulations;
The socket or circuit-breaker is easily accessible once the cooker has been installed.
Fitting on a power supply cable
Opening the terminal board:
Using a screwdriver, press on the side tabs of the terminal board cover;
Pull open the cover of the terminal board
To install the cable, proceed as follows:
Remove the wire clamp screw and the three contact screws L-N
Fasten the wires beneath the screw heads using the following colour scheme; Blue( N) Brown( L), Yellow- Green
Fasten the supply cable in place with the clamp and close the cover of the terminal board.