E0 ash every 4 seconds temperature sensor issue:
• Contact Leisure-Tec on 1300 07 2018
E1 ash every 4 seconds - low voltage & Battery Protection:
• An E1 will occur when the battery protection level has been reached.
i.e input voltage to low for protection setting, check power source voltage.
• Try on dierent power source (vehicle or 240V AC power).
If changing power source xed issue, then possible issue with original power source.
• Ensure cabling between fridge and battery is at least 1.5 mm2,
if the distance is more than 2 metres use at least 2.5 mm2 cable.
E2 ashes every 4 seconds - fan issue:
• Fan is drawing too many amps (over 0.6 amps), replace fan.
Contact Leisure-Tec on 1300 07 2018
E3 ashes every 4 seconds - compressor start issue:
• Unplug cable and allow unit to rest for 10 minutes.
• Try on dierent power source (vehicle or 240 V AC power).
• Electronic box fault.
• Compressor fault.
• If changing from 240v AC to 12v DC power or vice versa, if the change is done too quickly
without switching o the unit; the unit will show an error.
Just wait 5 minutes and it will automatically correct and run normally.
E4 ashes every 4 seconds - low motor speed:
• Reduce products/items inside unit.
• Move so unit is in a lower ambient temperature,
clean vents/ensure clear air ow over compressor.
• Fan fault.
• If changing from 240v AC to 12v DC power or vice versa, if the change is done too quickly
without switching o the unit; the unit will show an error.
Just wait 5 minutes and it will automatically correct and run normally.
E5 ashes every 4 seconds - over temperature:
• Ambient temperature too high.
• Clean vents/ensure clear air ow over compressor.
• Fan fault.
NOTE:
The status indicator will be green if running normal. If it changes to a ashing orange light,
this indicates that there is a change in status. There will also be a status indicator code
shown on the LED display.
page 10
Status Indicator
CCP FRIDGE·FREEZER
Loading ...
Loading ...