F2222 – 230v Control Panel Shown Below
SECTION IV
PRIOR TO USE
A. Remove any excess dust/dirt from exterior housing and control panel.
B. Be sure the HEPA Filter and Pre-Filters are installed properly with a positive seal.
C. Insure the unit is connected to a dedicated 20Amp, 120 volt circuit.
D. Make sure unit is safely positioned as not to impede any entrances or exits of the work area.
E. If applicable, check exhaust port connections for tight seal.
CAUTION: Insure your power cord is securely attached to the male recessed plug. If any movement
or play is detected, change power cord immediately! If connection remains loose, immediately
replace the male recessed plug.
OPERATION
A. When utilized in containment, the Novair should be positioned a minimum distance away from the
entrance and located towards the center of the containment.
B. When using a HEPA filter, insure the filter is correctly installed and sealed. Anchor and secure the filter
utilizing the supplied filter frame.
C. Install the Pleated Filter and Ring Filter into unit.
D. Position the unit on a flat level surface and secure the casters using the lock feature.
E. Insert the male end of your power cord into a 20 Amp dedicated outlet
F. To begin operation, depress the power switch to either the low or high position. Locate the differential
pressure gauge located on the control panel. The gauge will register between 2.0-2.5” of water column.
This is the initial reading when filters are new and unused. This reading will incrementally increase as
filters become loaded with dust and debris. When the gauge reaches 3.0” - 3.4” of water column; either
one or all of the filters are loaded and in need of replacement.
G. Pressing the power switch to the left will operate the unit in “Low” mode equivalent to 1200 CFM.
H. Pressing the power switch to the right will operate the unit in “High” mode equivalent to 2000 CFM.