SAFETY
Novatek Negative Air Machines are highly efficient systems designed to reduce air borne particulates. To
insure proper operation, the following safety precautions should be strictly adhered to:
A. Do not leave machine unattended when connected to a power source. Turn OFF electric supply and
disconnect from power source when not in use and/or before servicing.
B. Do not operate with damaged or malfunctioning parts. If the unit is not working as intended, return to an
Authorized Repair and Service Center.
NOTE: Always replace worn or damaged components with genuine NOVATEK parts. Failure to
comply could result in equipment failure and will void warranty.
C. Remove any loose clothing and adornments prior to operation.
D. Keep outer surfaces free of dirt and debris. Be sure all controls clean and functioning properly.
E. Turn off power prior to any filter inspection and replacement.
F. Do not operate unit with flammable or combustible liquids or gases present.
G. Do not operate the machine in wet conditions. Failure to do so could result in electrical shock or death.
H. Never operate the unit if there is any possibility of contact with the blower wheel.
I. It is the responsibility of the unit owner to ensure that all equipment is maintained in safe and efficient
operating condition.
J. Stacking of machines is limited to three units. Do not house stacked machines in areas hotter than 100
degrees Fahrenheit. (Failure to comply will void warranty.)
TROUBLESHOOTING
A. The unit is plugged in and turned on, but will not operate.
Inspect the circuit breaker located on the front control panel. If the center of the circuit breaker is
extended, this indicates the circuit breaker requires re-setting. Reset the circuit breaker by depressing
the center of the circuit breaker. If the center fails to remain depressed, replace the circuit breaker
immediately
B. If unit continues not to function.
Check the power supply in the work area. Be sure power is being supplied to the unit.
C. If at this point, unit still will not operate
Contact your nearest authorized Novatek service center.