Electrical Requirements
WARNING
To prevent an electric shock hazard, the power supply must meet
the specifications stated below. It is the owner’s responsibility
to make sure that the electrical service meets electrical require-
ments and that the electrical outlet has been properly installed.
◊ The cooktop is supplied with a factory installed, 40-inch power cord
with a, three-prong, grounding electrical plug. It is connected to the
chassis at the bottom right rear corner (see Chassis Bottom Diagram
below). It must be connected to a dedicated, grounded three-prong
electrical outlet installed by a licensed electrician.
◊ The electrical installation, including minimum supply wire size and
grounding, must be done in accordance with National Electric Code
ANSI/NFPA 70* and local codes and ordinances. A copy of this
standard may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
◊ The correct voltage, frequency and amperage must be supplied to
the electrical outlet according to the product data label located on the
bottom of the chassis. See the Gas and Electrical Requirements table
on this page for reference.
◊ Be certain to locate the electrical outlet so that the power may be
easily disconnected if the unit needs service.
Gas Supply Requirements
◊ Be certain that the cooktop being installed is correct for the gas
service being provided (natural gas or LP gas). Also, if operating
the cooktop at an altitude above 4000 ft. (1219 m) make sure it is
equipped for high altitude operation.
◊ Units equipped for LP operation have “LP” in the model number listed
on the product data label. See the Chassis Bottom Diagram for label
location.
◊ Units equipped for high altitude operation have an “H” at the end of
the model number listed on the product data label.
◊ Check your local building codes for the proper method of installation.
In the absence of local codes, this appliance should be installed in
accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54.
◊ An external manual shut-off valve must be installed between the gas
inlet and the cooktop for the purpose of turning on or shutting off gas
to the appliance.
◊ The cooktop comes from the factory with a regulator in the shipping
carton. Use only the regulator provided. The regulator must be
installed in the gas line that runs from the cooktop gas inlet to the gas
shut off valve.
◊ The regulator inlet accommodates a 3/4” gas line. The inlet to the
cooktop itself is equipped with a 3/4” male NPT fitting.
◊ The electrical and gas data on this page is for reference only. If the
above data does not agree with the product data label, use the data
on the product data label.
◊ The gas supply pressure for testing the regulator setting shall be
at least 1 inch water column (249 Pa) above the specified manifold
pressure.
MODEL
DYCT304G/NG
DYCT365G/NG
DYCT304G/LP
DYCT365G/LP
Gas type Natural LPG
Manifold
pressure
5” Water column 10” Water column
Min. gas supply Pres-
sure**
6” Water column 11” Water column
Max. gas supply pres-
sure
1/2 psi 1/2 psi
Total connected load 0.25 Amp. (0.03 kW) 0.25 Amp. (0.03 kW)
Circuit requirement
120 Vac,
60 Hz, 15 Amp.
120 Vac,
60 Hz, 15 Amp.
GAS AND ELECTRICAL REQUIREMENTS
UNDERNEATH
COOKTOP:
DYCT304G
13/16”
(2.1 cm)
3 3/4”
(9.5 cm)
Gas inlet
Power cord
Chassis
Front of cooktop
Top panel overhang
2 1/8”
(5.4 cm)
5/8”
(1.6 cm)
UNDERNEATH
COOKTOP:
DYCT365G
1”
(2.5 cm)
1”
(2.5 cm)
1 3/8”
(3.5 cm)
Gas inlet
Power cord in
Chassis
Front of cooktop
Top panel overhang
2 1/4”
(5.7 cm)