PROBLEM
Engine will not start
No electrical output
CAUSE
1. Low on fuel or oil.
2. Ignitionswitch in "Off" position.
3. Faultyspark plug.
4. Choke inwrong position.
5. Fuel shut-off valve in closed
position.
6, Unitloaded during start-up.
7. Spark plug wire loose.
1.
2.
Faultyreceptacle.
Circuit breaker kicked out.
CORRECTION
1. Add fuel or oil.
2. Turn to "ON" position
3. Replace spark plug.
4. Adjust choke accordingly.
5. Open fuel shut-off valve.
6. Remove load from unit.
7. Attach wire to spark plug.
1. Have Service Center replace.
2. Depress and reset.
3. Defective capacitor.
4. Faulty power cord.
3. Have Service Center replace
capacitor.
4. Repair or replace cord.
5. GFCI switch breaker kicked out (if 5. Depress and reset
equipped)
Repeated circuit breakertripping 1. Overload 1. Reduce load.
2, Faultycords or equipment. 2. Check for damaged, bare, or
frayed wires on equipment.
Replace.
Generator overheating 1. Generator overloaded. 1. Reduce load.
2. Insufflcientventilation. 2. Move to adequate supply of
fresh air.
No auto idle
DC does not have power with the
circuit breaker depressed
1, Faultysolenoid
2, Faulty idle control switch
3, Faulty windings in stator
4. Faulty circuit board
5. Faulty wire harness
1. Faulty rectifier
2. Faulty windings in stator
3. Faulty wire harness
1. Have Service Center replace.
2. Have Service Center replace.
3. Have Service Center replace.
4. Have Service Center replace.
5. Have Service Center replace
1. Have Service Center replace.
2. Have Service Center replace.
3. Have Service Center replace.