SYSTEM SPECIFICATION AND PERFORMANCE DATA
SHEET REFRIGERATOR WATER FILTER CARTRIDGE
MODEL 9005
Specifications
Service Flow Rate (maximum) ....................................................0.75 GPM (2.83 L/min)
Rated Service Life Model 9005 (maximum)................................500 gallons/1892 liters
MaximumOperating Temperature...............................................100° F/38° C
Minimum Operating Temperature................................................33° F/l° C
Minimum Pressure Requirement.................................................35 psi/138 kPa
MaximumOperating Pressure.....................................................120 psi/827 kPa
PERFORMANCE DATA
Substance
'Lead
Lead
Cyst
Turbidity
Lindane
Atrazine
Chlorine
Particulate**
2,4-D
Asbestos
Influent Challenge
Concentration
0.15 mg/L +/- 10%
0.15 mg/L +/- 10%
Minimum50,000/L
11+/-1 NTU
0.002 mg/L +/- 10%
0.009 mg/L +/- 10%
2.0 mg/L +/- 10%
at least 10,000
particles/mL
0.210 mg/L +/- 10%
107to 10Sfibers/L;fibersgreaterI
i
than !0 micrometersin length
Effluent Average %J Maximum
Average Reduction Effluent
0.001 mg/L 99.33% 0.001 mg/L
0.002 mg/L 98.66% 0.003 mg/L
lcount/mL 99.99% 3 count/mL
0.12 NTU 98.98% 0.18 NTU
0.00005 mg/L 97.62% 0.00005 mg/L
0.0002 mg/L 97.93% 0.0005 mg/L
0.09 mg/L 95.26% 0.17 mg/L
900 count/mL 99.66% 2400 count/mL
45.45 ug/L 84.42% 100 ug/L
0.16 MFL/mL 99.96% 0.16 MFL/mL
Min. Required Inlet
Reduction pH
0.010 mg/L 6.5
0.010 mg/L 8.5
> 99.95% NA
O.5 NTU NA
I
0.00002 mg/L ! NA
0.003 mg/L NA
>75% NA
>85% NA
0.0017 mg/L NA
99% NA
Tested using a flow rate of 0.75 GPM (2.83 L/rain.) and a maximum pressure of 120 psi (827 kPa)
under standard laboratory conditions, however, actual performance may vary. Health Claim
Performance tested and certified by NSF International
** Particle size range classification of test. Particles used were 0.5 -1 microns.
State of California
Department of Health Sewices
Water Treatment Device
Certificate Number
01 - 1486
Date Issued: September 21. 2001
Date Revised: March 20, 2O02
GENERAL USE
CONDITIONS
Read this PerformanceData Sheet and
compare the capabilities of this
refrigeratorwith your actual water
treatment needs.
DO NOT use this product where water
is microbiologicallyunsafe or of
unknown qualitywithout adequate
disinfection installed before or after
filtration system. Systemscertified
for cyst reduction may be used on
disinfected water that may contain
filterable cysts.
Use only with cold water supply.
Check for compliance with the state
and local laws and regulations.
The retractable water filtration system
uses a 9005 replacement cartridge (see
Sears contact information at the back of
your Use and Care Guide to order).
Timely replacement of filter cartridge is
essential for performance satisfaction
from this filtration system. Please refer
to the applicable section in this Use and
Care Guide for general operation,
maintenance requirements and
troubleshooting.
This system has been tested according
to ANSI/NSF 42 and 53 for reduction of
the substances listed below. The
concentrationof the indicated
substancesin water entering the system
was reducedto a concentration less than
or equal to the permissiblelimit for water
leaving the system, as specified in
ANSI/NSF 42 and 53.
wFso-wl500 wFso 500gal
WFS0-N[3CO WFSO 300 gat
WFS0-KWlSO( 40 9005 300g_l
WFS0-KNI3CO 4_ _O05 300g_l
OWF_0-WlSO0 JVmS 5(_ _al
OWFSO-_I30a OWF5 J_Ogal
Manuf_ctu_r: PeriL.pure{a_q,o=,=o
3he water z_a=ment device,s) IJs_ _ this certW_te have met the tt_thtg _qui_¢nts pbrsua_t to Section 116830 of the
Health _.d Safety Caaa for th_ foLly*tug Ueaah _lated _ma_n_ts:
_L_3&t,_J_ IJ_9_f.2RaSl_ei_lConl_tnan_
Cysls Asb_
Llndan_
Tested and certified by NSF International against ANSI/NSF Standards 42 and 53 in
models WF50-KNI300 and WF50-KWl500 for the reduction of:
Standard No. 42: Aesthetic Effects
Taste and Odor Reduction
Chlorine Reduction
Mechanical Filtration Unit
Particulate Reduction Class 1
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead, Atrazine, Lindane and 2, 4-D Reduction
Mechanical Filtration Unit
Cyst, Turbidity and Asbestos Reduction
@
PentaPure
INI ()_[)RAI_I)
1000ApolloRoad
Eagan, Minnesota U.S.A.
EPAEST#35917-MN-1