5
INSTALLATION
installation. A Floor Protector of 1” (26 mm) thick is
recommended for this installation. Canadian installations
require 18” (450 mm) in front of the unit.
BB
D
C
A
B B
C
Dimensions in mm
A Rear (through wall) 1 25
B Side 6 152
C Front *6 *152
D Rear (interior vertical) 2 50
* Canada installation requires 18”
(450 mm) in front of the unit.
CLEARANCES
Your pellet stove has been tested and listed for installation
in residential, mobile home, and alcove applications in
accordance with the clearances given in this manual.
For safety reasons, please adhere to the installation
clearances and restrictions. Any reduction in clearance to
combustibles may only be done by means approved by a
regulatory authority.
E
BACK WALL
BACK WALL
SIDEWALL
SIDEWALL
F
F
G
G
E
ADJACENT WALL
ADJACENT WALL
H
ADJACENT WALL
H
H
ADJACENT WALL
H
J
in mm
PARALLEL
E Backwall to unit 2 50
F Sidewall to ue 13 330
G
Sidewall to top edge of
unit
8 203
CORNER H Adjacent wall to unit 8 203
ALCOVE J Alcove depth 36 914
OUTSIDE AIR SUPPLY (OPTIONAL, UNLESS INSTALLING
IN A MOBILE HOME)
ATTENTION:
DO NOT VENT UNDER ANY PORCH, DECK, AWNING,
OR IN ANY SEMI ENCLOSED OR ROOFED AREA. DOING
SO MAY RESULT IN UNPREDICTABLE AIRFLOW AT THE
VENT CAP UNDER CERTAIN CONDITIONS AND CAN
AFFECT THE PERFORMANCE OF YOUR STOVE, AS
WELL AS, OTHER UNFORESEEABLE ISSUES.
Depending on your location and home construction,
outside air may be necessary for optimal performance.
Your stove is approved to be installed with an outside air
intake (69FAK) which is necessary for a mobile home.
You can purchase the 69FAK through your heater dealer.
Installation instructions are supplied with the air intake kit.
SECURING APPLIANCE TO THE FLOOR
Use the designated holes to secure the unit to the oor.
MOBILE HOME
MOUNTING BOLT HOLES