Installation - ventilation and clearances
In all circumstances, make sure the cooktop is well ventilated as they do
generate a fair amount of heat during use. DO NOT install the cooktop if
glass is cracked or any other damaged realised.
The safety distance between the cooktop and the cupboard above the cooktop
should be at least 760mm. Any rangehood installed above the cooktop should
be no less than 650mm above the surface of the cooktop.
NOTE: If the cooktop is installed above an opening drawer or cupboard a
thermal protection heat barrier MUST BE tted 50mm below the base of the
underside of the cooktop to avoid possibly scalding when accessing the drawer
or cupboard.
Refer to the below illustration and table re other ventilation and clearance
requirement.
A (mm)
B (mm) C (mm) D E
760 *
50 Min. 20 Min. Air intake Air outlet
* This dimension relates to adjoining cupboards. For a rangehood installed
above the cooktop the minimum distance is 650mm from cooktop surface
highest point to the bottom of the rangehood lters.
After the cooktop has been installed, make sure that
• The power supply cable is not accessible through cupboard doors or
drawers.
• There is adequate ow of air from outside the cabinetry to the base of the
cooktop.