WARNING: Only change the voltage selector switch with the main AC circuit
breaker OFF. The generator can be seriously damaged if the voltage selector switch
is changed with the breaker ON.
Voltage Selector Switch
This generator features Power Boost Technology, which gives the
user the ability to double the power in the generator for more
heavy duty applications.
The voltage selector switches the dual 120V AC windings of
the generator to produce “120V ONLY” or “120/240V”. If a 240V
appliance is connected to the 4-prong receptacle, the switch must
be in the “120/240V” position. If only 120V appliances are being
connected to the generator select the “120V ONLY” position to
double the 120V amperage and automatically balance the load.
Idle control
The idle control feature lowers the RPM of the generator
when there is no load to save gas and decrease engine
noise.
When a load is applied, the engine will resume normal
speed to provide usable power.
Turn on the idle control when using intermittent loads like
power tools and air compressors.
The idle control feature is designed for gasoline only use.
Idle Control Usage
WARNING: Power is unusable when idle control is engaged.
DO NOT use the idle control function when using the generator for backup
house power.
Idle control function will cause massive uctuations in voltage and hertz.
Low amperage loads may not trigger the idle up function.