9. SPACE HEATER INSTRUCTION
9.1 TO START HEATER
i. Fill fuel tank with appropriate fuel.
ii. Fit fuel cap.
iii. Ensuring heater switch is in the “off” position:-
- Plug power cable into mains supply.
- Extension Cable Wire Size Requirements:
- 6 to 10 feet (1.8 to 3 metres) long, use 1.0mm gauge cable.
- 11 to 100 feet (3.4 to 30.53 metres) long, use 1.3mm gauge cable.
- 101 to 200 feet (30.8 to 61 metres) long, use 1.6mm gauge cable.
iv. Turn THERMOSTAT CONTROL  to desired setting and press power switch to "ON"
position. Power indicator lamp will light and heater will start.
If heater does not start, the thermostat setting may be too low. Turn THERMOSTAT
CONTROL  to higher position to start heater. If heater still does not start, turn power switch
to OFF and then to ON position.
9.2 TO SHUT DOWN HEATER
Turn power switch to "OFF" and unplug power cable.
9.3 TO RESTART HEATER
i. Wait 10 seconds after stopping heater.
ii. Repeat steps under, "TO START HEATER."
9.4 FUEL SYSTEM
This heater is equipped with an electric air pump that forces air through the air line connected to
the fuel intake, and then through a nozzle in the burner head. When air passes in front of the fuel
intake, it causes fuel to rise from the tank and into the burner nozzle.
This fuel and air mixture is then sprayed into the combustion chamber in a fine mist.
The electronic ignitor sends voltage to a specially designed spark plug. The spark plug ignites the
fuel and air mixture described.
The heavy duty motor turns a fan that forces air into and around the combustion chamber. Here,
the air is heated and then forced out the front of the heater.
9.5 THE SAFETY SYSTEM
Temperature Limit Control: This heater is equipped with a Temperature Limit Control designed to
turn the heater off should the internal temperature rise to an unsafe level. If this device activates
and turns your heater off, it may require service.
Once the temperature falls below the reset temperature, you will be able to start your heater.
Electrical System Protection: This heater's electrical system is protected by a fuse mounted to the
PCB Assembly that protects it and other electrical components from damage. If your heater fails to
operate, have this fuse checked first and replace as needed.
Flame-Out Sensor: Utilizes a photocell to monitor the flame in burn chamber during normal
operation. It will cause the heater to shut off should the burner flame extinguish.