Viking VURD1441D 24" Refrigerated Drawer

User Manual - Page 3

For VURD1441D.

PDF File Manual, 25 pages, Download pdf file

Loading ...
Loading ...
3
UNDERCOUNTER CABINET CUTOUT
AA
24” (61.0 cm)*
BB
Min. 34-1/4” (87.0 cm)
Max. 35” (88.9 cm)
CC
24” (61.0 cm)
Retain for Future Reference
IMPORTANT - PLEASE READ AND FOLLOW
Before beginning, please read these instructions completely and carefully.
Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty.
Please observe all local and national codes and ordinances.
Please ensure that this product is properly grounded.
The installer should leave these instructions with the consumer who should retain for local inspector’s use and for future reference.
TToo rreedduuccee tthhee rriisskk ooff ffiirree,, eelleeccttrriiccaall sshhoocckk,, oorr iinnjjuurryy wwhheenn uussiinngg yyoouurr rreeffrriiggeerraatteedd ddrraawweerr,, ffoollllooww bbaassiicc pprreeccaauuttiioonnss
iinncclluuddiinngg tthhee ffoolllloowwiinngg::
•FOR YOUR SAFETY•
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR
ANY OTHER APPLIANCE. THE FUMES CAN CREATE A FIRE HAZARD OR EXPLOSION.
IItt iiss yyoouurr rreessppoonnssiibbiilliittyy ttoo bbee ssuurree yyoouurr rreeffrriiggeerraatteedd ddrraawweerr iiss::
•located so the front is not blocked to restrict incoming or discharge air flow.
•properly leveled.
•located in a well ventilated area.
•connected to the proper kind of outlet, with the correct electric supply and grounding. A 115 volt, 60 Hz, 15 amp
fused electrical supply is required.
NNOOTTEE::
Time delay fuse or circuit breaker is recommended.
•not used by anyone unable to operate it properly.
•used only for its intended purpose.
•properly maintained.
•SAVE THESE INSTRUCTIONS•
SUFFOCATION HAZARD
Remove doors from your old refrigerated drawer. Failure to do so can
result in child entrapment, which can cause death or brain damage.
IMPORTANT: Child entrapment and suffocation are not problems of the
past. Junked or abandoned refrigerated drawers are still dangerous, even if
they will sit for just a few days. If you are getting rid of your refrigerated
drawer, please follow the instructions below to help prevent accidents.
BEFORE YOU THROW AWAY YOUR OLD REFRIGERATION PRODUCT:
•Take off the doors.
•Leave the shelves in place so that children may not easily climb inside.
2
B
C
A
*
*
Cabinet Cutout
*Optional: Cutout
for electrical outlet
can be placed in
adjacent cabinetry.
DANGER
WARNING
A GFI shall be used if required by NFPA-70 (National Electric Code), federal/state/local laws, or local
ordinances.
The required use of a GFI is normally related to the location of a receptacle with respect to any
significant sources of water or moisture.
Viking Range Corporation will NOT warranty any problems resulting from GFI outlets which are not
installed properly or do not meet the requirements below.
If the use of a GFI is required
, it should be:
Of the receptacle type (breaker type or portable type NOT recommended)
Used with permanent wiring only (temporary or portable wiring NOT recommended)
On a dedicated circuit (no other receptacles, switches or loads in the circuit)
Connected to a standard breaker of appropriate size (GFI breaker of the same size NOT recommended)
Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard)
In good condition and free from any loose-fitting gaskets (if applicable in outdoor situations)
Protected from moisture (water, steam, high humidity) as much as reasonably possible
PROPER DISPOSAL OF YOUR OLD REFRIGERATION PRODUCT
Loading ...
Loading ...
Loading ...