Cabinet Dimensions
Cabinet opening dimensions shown are for 25" (64 cm) countertop depth, 24" (61 cm) base cabinet depth and 36" (91.4 cm) countertop
height.
If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination
installation instructions for dimensional clearances above the cooktop surface.
Freestanding Range
A freestanding range may be installed next to combustible walls
with zero clearance.
Slide-in Range
£
........_ii!iiiliii_
_Hiiliii iii {iiii
_iiiiii'iii]iii
\\
D
G
I
I
A. !3" (33 cm) upper cabinet
depth
B. 30" (76.2 cm) min. opening
width
C. For minimum clearance to the
top of the cooktop,
see NOTE*.
D. 30" (76.2 cm) min. opening
width
E. Junction box - 8" (20.3 cm)
to 22" (55.9 cm) from either
cabinet, 7" (!7.8 cm) max.
from floor
F. Cabinet door or hinge should
not extend into the cutout.
A. 13" (33 cm) upper cabinet
depth
B. 30" (76.2 cm) min. opening
width
C. For minimum clearance to
the top of the cooktop,
see NOTE*
D. 223/4'' (57.8 cm) opening
depth
E. Square cut or V4"(6.2 cm) radius
both corners
F. 30" (76.2 cm) min. opening
width
G. Junction box - 8" (20.3 cm) to
22" (55.9 cm) from either
cabinet, 7" (!7.8 cm) max. from
floor
H. Cabinet door or hinge should
not extend into cutouL
NOTE: 24" (61 cm) minimum when bottom of wood or metal cabinet is protected by not less than 1/4"(0.64 cm) flame retardant
millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or
0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an unprotected wood or metal cabinet.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate and wire gauge is in accordance
with local codes.
Do not use an extension cord.
Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
WARNING: Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. Check with a
qualified electrician or service technician if you are in doubt as to
whether the appliance is properly grounded. Do not modify the
power supply cord plug. If it will not fit the outlet, have a proper
outlet installed by a qualified electrician.
Electrical Connection
To properly install your range, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
Range must be connected to the proper electrical voltage
and frequency as specified on the model/serial number rating
plate. The model/serial number rating plate is located on the
oven frame behind the storage drawer panel. Refer to the
figures in the "Product Dimensions" section of the "Location
Requirements" section.