Installation and connection en-us
7
Before using for the first time
1. Remove information material, adhesive tape and
protective foil.
2. Clean the appliance.
~ "Cleaning" on page 17
Electrical connection
9 CAUTION!
Do not connect the appliance to electronic
energy saver plugs.
Note: You can connect the appliance to mains-
controlled and sine-controlled inverters.
Mains-controlled inverters are used for photovoltaic
systems which are connected directly to the national
grid. Sine-controlled inverters must be used for
isolated applications. Isolated applications, e.g. on
ships or in mountain lodges, are not directly
connected to the national grid.
1. After installing the appliance, wait at least 1 hour
before connecting it to prevent damaging the
compressor.
2. Check that the outlet was installed according to
the regulations and complies with the
requirements.
Requirements for outlets
Maximum simultaneous load
3. Connect the appliance to an outlet near the
appliance.
The outlet must also be freely accessible
following installation of the appliance.
9 WARNING
RISK OF ELECTRIC SHOCK!
Never use multiple outlets, extension leads
or adapters.
The appliance must be correctly grounded.
Never cut through or remove the third
(ground) conductor of the power cord.
9 WARNING
RISK OF ELECTRIC SHOCK!
If the length of the power cord is inadequate,
never use multiple outlets or extension
leads. Instead, please contact Customer
Service for alternatives.
Outlet with 110 V ... 120 V
Protective
conductor
60 Hz
Fuse 10 A ... 16 A
Appliance 6 A