I. THREE-WIRE ELECTRICAL
CONNECTION TO RECEPTACLE
Use a 3-wire power supply cord:
Fire Hazard
Use a new UL approved 30 ampere
power supply cord.
Use a UL approved strain relief.
Disconnect power before making
electrical connections.
Connect neutral wire (white or center
wire) to center terminal (silver).
Ground wire (green or bare wire)
must be connected to green ground
connector.
Connect remaining 2 supply wires to
remaining 2 terminals (gold).
Securely tighten all electrical
connections.
Failure to do so can result in death,
fire, or electrical shock.
This blade connected
to this conductor
Neutral _ i..............
Local codes may permit the use of
a U.L.-listed, 120/240-volt minimum,
30-ampere, dryer power supply cord
kit (pigtail). Power supply cord should
be type SRD or SRDT and be at least
four feet long. The wires that connect
to the dryer must end with ring terminals
or spade terminals with upturned ends.
Do not use an extension cord with
this dryer.
Do not connect plug end of power
supply cord into a live receptacle
before connecting power supply cord
to dryer terminal block.
The power supply cord must have three,
No.-10 copper wires to match a three-wire
receptacle of NEMA Type 10-30R.
Spade terminals
with upturned ends
(OR ring terminals)
/
Connect wire
with ends
iacing you
Ring
terminals
(OR spade
terminals)
_-inch, U.L.-listed Neutral wire
strain relief (white)
Three-Wire Power Supply Cord
I4
Three-wire receptacle
(NEMA TypelO-3OR)