Through your wall Further to your various ducting options, below are some tips on how to
correctly duct your rangehood:
– Always use correctly sized ducting–DO NOT reduce the size of the ducting
– Always use solid ducting
– Always use non-flammable ducting
– Always duct to the outside atmosphere
– Do not use flexible ducting
– Do not duct into the ceiling space—always vent to the outside atmosphere.
– Avoid sharp 90 degree bends as much as possible, use 45 degree bends
instead wherever possible
– Duct to the outside atmosphere using the shortest duct run possible
– Use cylindrical ducting whenever possible
Positioning the rangehood Installation heights
–
Over gas and electric cookers, Esatto recommends our
rangehoods to be mounted at a height of between
600-800mm above the cooking surface.
– Electric cooktops must have a minimum height of 600mm from the
underside of the rangehood to the cooktop face.
– Gas cooktops must have a minimum of 650mm from the burner to the
underside of the rangedhood.
– Over open flame grillers or barbecues, the Gas Regulations require the
fi lters of the rangehood to be at least 1200mm above the cooking surface.
Installing the rangehood – The typical installation method for your undermount rangehood is into a
purpose built overhead/wall cabinet.
– Using a jigsaw, create the required cut-out for your undermount
rangehood, as per the following:
–
EUM52 52cm: 490 × 250mm
–
EUM75 75cm: 715 × 250mm
–
EUM90 90cm: 865 × 250mm
– Make sure the cut-out is at least 35mm from the cabinet edge.
–
Remove the grease fi lter and remove the 2 screws on the panel.
– Screw the rangehood into the cabinet using 8 screws (supplied).
–
Re-fi t the panel with the 2 screws (previously removed).