8
Through your wall Further to your various ducting options, below are some tips on how to
correctly duct your rangehood:
Always use correctly sized ducting–DO NOT reduce the size of the ducting
Always use solid ducting
Always use non-flammable ducting
Always duct to the outside atmosphere
Do not use flexible ducting
Do not duct into the ceiling space—always vent to the outside atmosphere.
Avoid sharp 90 degree bends as much as possible, use 45 degree bends
instead wherever possible
Duct to the outside atmosphere using the shortest duct run possible
Use cylindrical ducting whenever possible
Positioning the rangehood Installation heights
Over gas and electric cookers, Esatto recommends our
rangehoods to be mounted at a height of between
600-800mm above the cooking surface.
Electric cooktops must have a minimum height of 600mm from the
underside of the rangehood to the cooktop face.
Gas cooktops must have a minimum of 650mm from the burner to the
underside of the rangedhood.
Over open flame grillers or barbecues, the Gas Regulations require the
lters of the rangehood to be at least 1200mm above the cooking surface.
Installing the rangehood The typical installation method for your undermount rangehood is into a
purpose built overhead/wall cabinet.
Using a jigsaw, create the required cut-out for your undermount
rangehood, as per the following:
EUM52 52cm: 490 × 250mm
EUM75 75cm: 715 × 250mm
EUM90 90cm: 865 × 250mm
Make sure the cut-out is at least 35mm from the cabinet edge.
Remove the grease fi lter and remove the 2 screws on the panel.
Screw the rangehood into the cabinet using 8 screws (supplied).
Re-fi t the panel with the 2 screws (previously removed).
INSTALLATION INSTRUCTIONS
CONTINUED