Loading ...
Loading ...
Loading ...
36
20306750
Designer Series Direct Vent Gas Fireplace
To Junction Box
In Fireplace
WHITE
BLACK
WHITE
BLACK
BLACK
WHITE
GREEN
Connector
Pin To Contro l Box
{
{
Light
Optional
AUX
FP2708
BLOTKSTSC fan wiring
Blower (300w Max)
Blower (300w Max)
FIREPLACE INSTALLATION
Figure 55 -
BLOTSTSC Blower Wiring Diagram
(shown with 2 blower kits)
FP2708
Control Board
NOTE
The black and white wires on the AC box
wiring harness are marked ‘Blower’, ‘Light’
and ‘Aux’. It is important to use the wires
marked ‘Blower or the control will not work
correctly.
WARNING
Electrical connections should only be
performed by a qualied licensed electrician.
Main power supply must be turned off before
connecting the fan to the main electrical
power supply or performing service.
BLOTSTSC SIGNATURE COMMAND SINGLE BLOWER
Electrical Grounding Instructions: This
appliance is equipped with a three-prong
(grounding) plug for your protection against
shock hazard and should be plugged directly
into a properly grounded three-prong
receptacle.
WARNING
AC Module
The BLOTSDVSC Blower Kit requires the SCSACM A/C
Module and the TSFSC remote to install and operate this
kit. Refer to blower instructions for installation.
NOTE: If two (2) blowers are required with the Signature
Command System SCSACM & TSFSC remote, two (2)
BLOTSTSC Kits must be purchased.
Loading ...
Loading ...
Loading ...