Loading ...
Loading ...
Loading ...
Base Grille Water Filtration System
Model WF-LC400V/LC400V Capacity 400 Gallons (1514 Liters)
(_ System tested and certified by NSF International against NSF/ANSI Standard
42 for the reduction of Chlorine Taste and Odor, Nominal Particulate Class I*;
and against NSF/ANSl Standard 53 for the reduction of Lead, Mercury,
Atrazine, Benzene, Toxaphene, p-dichlorobenzene, 2, 4-D, Cysts, Turbidity and
Asbestos.
This system has been tested according to NSF/ANSl Standards 42 and 53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance Reduction NSF Reduction Average Influent Challenge Maximum Product Minimum % Average %
Aesthetic Effects Requirements Influent Concentration Effluent Water Reduction Reduction
Chlorine Taste/Odor _>50% 2.1 mg/L 2.0 mg/L _+10% 0.06 mg/L 0.05 mg/L 97.1% 97.6%
Nominal Particulate Class I* _>85% 5,366,667/mL Atparticles/mLleast10,000 4,100/mL** 2,300/mL 99.3% 99.9%
Contaminant NSF Reduction Average Influent Challenge Maximum Product Minimum % Average %
Reduction Requirements Influent Concentration Effluent Water Reduction Reduction
Lead: @ pH 6.5 0.01 mg/L 0.16 mg/L1- 0.15 mg/L _+10% 0.001 mg/L 0.001 mg/L 99.3% 99.35%
Lead: @ pH 8.5 0.01 mg/L 0.15 mg/L1- 0.15 mg/L _+10% 0.001 mg/L 0.001 mg/L 99.2% 99.31%
Mercury: @ pH 6.5 0.002 mg/L 0.0061 mg/L 0.006 mg/L _+10% 0.0004 mg/L 0.0003 mg/L 93.5% 96.7%
Mercury: @ pH 8.5 0.002 mg/L 0.0057 mg/L 0.006 mg/L _+10% 0.0008 mg/L 0.00051 mg/L 85.8% 91.2%
Benzene 0.005 mg/L 0.0138 mg/L 0.015 _+10% 0.0005 mg/L 0.005 mg/L 96.3% 96.3%
o-dichlorobenzene 0.075 mg/L 0.220 mg/L 0.225 _+10% 0.0005 mg/L 0.0005 mg/L 99.7% 99.7%
Toxaphene 0.003 mg/L 0.014 mg/L 0.015 _+10% 0.0014 mg/L 0.001 mg/L 90% 92.96%
Atrazine 0.003 mg/L 0.009 mg/L 0.009 mg/L _+10% 0.0013 mg/L 0.00036 mg/L 85.6% 85.6%
2, 4-D 0.07 mg/L 0.197 mg/L 0.215 _+10% 0.058 mg/L 0.0137 mg/L 70.6% 93.06%
Asbestos 99% 26 x 107 107to 10_fibers/Ll-1 - 0.18 x 107 mg/L 0.18 x 107 mg/L 99.93% 99.93%
Cysts$ 99.95% 111,000/mL 50,000/L min. 1 mg/L 1 mg/L 99.99% 99.99%
Turbidity 0.5 NTU 11.08 NTU 11 _+1 NTU 0.13 NTU 0.078 NTU 98.8% 99.3%
Test Parameters: pH = 7.5 _+0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure =
Temp. = 63°F (17.2°C).
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Flush for 5 minutes prior to use.
Model WF-LC400V: The filter monitor system measures the
amount of water that passes through the filter and alerts you to
replace the filter. When 90% of the filter's rated life is used, the
filter indicator light changes from green to yellow. When 100% of
the filter's rated life is used, the filter indicator light changes from
yellow to red, and it is recommended that you replace the filter.
Use replacement cartridge LC400V, part #9010. 2007 suggested
retail price of $39.99 U.S.A. Prices are subject to change without
notice.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system. Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.
Refer to the front cover or "Accessories" section for the
Manufacturer's name, address and telephone number.
60 psig (413.7 kPa).
Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Note that while the testing was performed under standard
laboratory conditions, actual performance may vary.
Application Guidelines/Water Supply Parameters
Water Supply City or Well
Water Pressure 30 - 120 psi (207 - 827 kPa)
Water Temperature 33 ° - 100°F (0.6 ° - 37.8°C)
Service Flow Rate 0.5 gpm (1.89 L/min.) @ 60 psi
*Class I particle size: >0.5 to <1 um
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
1-These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
1-1-Fibers greater than 10 um in length
SBased on the use of Cryptosporidium parvum oocysts
® NSF is a registered trademark of NSF International.
24
Loading ...
Loading ...
Loading ...