Maytag MHN30PDCWW0 27 Inch Commercial Washer

INSTALLATIONINSTRUCTIONS - Page 6

For MHN30PDCWW0.

PDF File Manual, 32 pages, Read Online | Download pdf file

MHN30PDCWW0 photo
Loading ...
Loading ...
Loading ...
6
Shipping bolt with plastic spacer
INSTALLATION
INSTRUCTIONS
Remove Transport System
IMPORTANT: Position the washer so that the rear of the washer
is within approximately 3 ft. (900 mm) of its final location.
There are 4 shipping bolts in the rear panel of the washer that
support the suspension system during transportation. These
bolts also retain the power cord inside the washer until the bolts
are removed.
1. Keep the washer in the upright position while removing the
shipping bolts.
Shipping bolt
Shipping bolt
Electrical Requirements
A 120 volt, 60 Hz., AC only, 15- or 20-amp, fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended. It is recommended that a separate circuit
serving only this washer be provided.
This washer is equipped with a power supply cord having
a 3 prong grounding plug.
To minimize possible shock hazard, the cord must be
plugged into a mating, 3 prong, grounding-type outlet,
grounded in accordance with local codes and ordinances.
If a mating outlet is not available, it is the personal
responsibility and obligation of the customer to have the
properly grounded outlet installed by a qualified electrician.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
Do not ground to a gas pipe.
Check with a qualified electrician if you are not sure the
washer is properly grounded.
Do not have a fuse in the neutral or ground circuit.
Loading ...
Loading ...
Loading ...