To convert the rotissiere infrared burner:
1. Remove the back cover from
the unit to expose the orifice
hood to the infrared burner.
2. Remove the gas orifice hood
located on the grill.
3. Replace with the gas orifice
hood supplied in the
conversion kit.
4. Replace the back cover.
Orifice hood
Back
Cover
Landing ledge
Grill Burner /
Side Burner
Orifice hoods
Rear side
of control
panel
Smoker Burner
Orifice hood
To convert grill burners, side burner and smoker burner:
1. Remove all grates, flavor generators and stainless steel burners
from the unit.
2. Look into the burner box back toward the control panel in order
to located the orifice hoods. Remove the gas orifice hoods
located on the grill burner valves.
3. Replace the orifice hoods with the correct gas orifice hoods
supplied in the conversion kit. (See chart)
4. Replace the stainless steel burners, flavor generators and
grates.
NOTE:
For installation in areas with altitudes greater than 2000 feet, the orifices must be derated at 4% for every
1000 feet above 2000 feet.
3
Natural LP/Propane
Orifice Hood Orifice Hood
Natural LP/Propane
Orifice Hood Orifice Hood
Grill
Burners (3) - 40 (3) - #54
Smoker
Burners (2) - #51 (2) - #62
Side
Burners (2) - #49 (2) - #57
VGBQ/CVGBQ T/T1/E AND 100/300 SERIES CONVERSIONS
To check LP/Propane to Natural Conversion of the rotissiere
infrared burner:
Ignite the rotissere burner and set it to low. If the burner will not
hold a flame, it will be necessary to adjust the low setting. Remove
the control panel to expose the rotissiere safety valve. Using a small
flat head screwdriver turn the adjustment screw counterclockwse.
Visually check the flame. When the burner is able to hold a flame
on the low setting, the setting is complete. Replace the control
panel.
adjustment
screw
(1) or (2) - #48 (1) or (2) - #57
Infrared
Burner