12. TROUBLESHOOTING
12.1 TROUBLESHOOTING GUIDE
Problems
Tool will not operate. Air
flows slightly from
exhaust. Spindle turns
freely.
Tool runs slowly. Air flows
freely from exhaust.
Rotor vane seized. Pour air tool lubricating oil
into air inlet.
Operate tool in short
bursts.
Tap motor housing gently
with plastic mallet.
If still not functional,
return to service centre.
Motor or throttle seized
with dirt.
Check for dirt in air inlet.
Pour air tool lubricating oil
into air inlet.
Operate trigger in short
bursts.
Disconnect air line supply,
then turn spindle by hand.
Reconnect air supply.
If motor fails to turn return
to service centre.
Possible cause Required action
Spindle seized. Motor vane broken. Return to service centre.
Tool will not shut off. ‘O’ rings throttle valve
dislodged from seat inlet
valve.
Replace ‘O’ ring or return
to service centre.
We recommend the
use of Draper Air
Tool Oil:
500ml Stock No.34681
1Litre Stock No.34682
250ml Stock No.34679
- 16 -