11. MAINTENANCE
11.1 EVERY-DAY MAINTENANCE CHECKS
Before connection to the air supply:
• Drain the compressor reservoir of condensate.
• Drain the air lines of condensate.
• Drain the combined separator filter, regulator, water trap.
• Fill up the combined separator filter, regulator, lubricant reservoir.
• Check the line pressure is correct for the tool.
11.2 AFTER USE MAINTENANCE CHECKS
– Repeat the above procedures.
– Lubricate the tool with approximately 1.5ml of oil directly down the air inlet.
Warning!
● Disconnect from the air supply before carrying out any adjustments, servicing or
maintenance.
● Never use any sockets or accessories that are not hardened for impact use.