4A. Wiring Instructions (3-Wire Connection)
1. Remove the three (3) loose nuts on the terminal block
usinga 3/8" nut driveror socket.
NOTE: Do not loosenthenuts which secure the factory
installed range wiring to the terminal block. Electrical
failure or loss of electrical connection may occur if nuts
are loosened.
2. Using the nuts removed in step 1, connect the cable or
copper power supply cord to the three (3) studs on the
terminal block, aslocal codes require. The neutral (white)
wire or center wire must be connected to the center
terminal.
3. Make sure all nuts are tightened securely.
4. Replace the rear access cover.
GROUNDING INSTRUCTIONS:
A ground link is installed on this range which connects the
center terminal of the terminal block (neutral) to the chassis.
The ground link is not visible in the picture below but is
connected to the range by the center, lowest screw (shown in
picture below). The ground link must not be removed unless
national or local codes do not permit use of ground link.
NOTE: If the ground link is removed for any reason, a
separate ground wire must be connected to the separate
ground screw attached to the range chassis and to an
adequate ground source.
3-Wire
Connection
4B. Wiring Instructions (4-Wire Connection)
Ifconnectingtoa 4-wireelectricalsystem(newbranch-circuit
or mobilehome requires4 wire connection):
1. Remove the three (3) loose nuts on the terminal block
usinga 3/8" nutdriverorsocket. Fromthe centerstudon
theterminalblock,removethesecondnutandthecopper
groundstrap. Replacethenutthatheldthegroundstrap
to the terminalblock.
NOTE: Do not loosen the second nut on line 1 or line2
which secure the factory installed range wiring to the
terminal block. Electrical failure or loss of electrical
connection may occurif nuts are loosened.
2. Remove the ground screw torelease the copper ground
strap from the appliance.
3. Discard the ground strap. Connect the ground wire
(green) of the copper power supply cord to the frame of
the appliance with theground screw, using thesame hole
in the frame where the ground strap was removed.
4. Using the nuts removed in step 1, connect the neutral
(white) wire ofthe copper power supply cordto the center
silver colored stud on the terminal block.
5. Connect the final two (2) wires to the outer studs on the
terminal block.
6. Make sure all nuts are tightened securely.
7. Replace the rear access cover.
4-Wire
Connection
Terminal
Terminal
\
3-Wire Copper Power Supply Cord.
To Fused Disconnect Box or Approved
Wiring Device for Copper Supply Cord.
4-Wire Copper Power Supply Cord.
To Fused Disconnect Box or Approved
Wiring Device for Copper Supply Cord.
Insulated
Copper
Ground
Wire