Performance Data Sheet
GE SmartWater Filtration System
GWF Cartridge
Health Claim Performance Certified by NSF/ANSI*
qOO% safety factors built in for unmetered usage)
Standard No. 42: Aesthetic Effects
Paxmneter
Average
98.90%
Chhwine
T&O -
Particulate** 98.00% 96.10%
USEPA
MCL
USEPAParameter
hlfluent
Challenge
1.9 ppm
200,000
Effluent
Average
0.02 pi_m
3,978
Staaadaxd No. 53: Health Effects
blfluent Effluent
MaJdlnlun
0.05 pI_m
7,800
Tmq)idiw
Cysts
I,ead at pH 6.5
I,ead at pH 8.5
I,indane
Atrazine
2,4-D
Asbestos
% Reduction
Mbmnum
97.37%
% Reduction
MCL
1 NTU***
99.95% Reduction
15 ppb
15 ppb
0.0002 ppm
0.00:4 ppm
0.100 ppm
99%
Challenge
24.3 NTU
105,750
160 ppb
150 ppb
0.00062 ppm
0.0084 ppm
0.272 ppm
690 MFI,/ml
Average
0.07 NTU
26
1 ppb
1.8 ppb
0.00005 ppm
0.002 ppm
0.042 ppm
0.32 MFI,/ml
Maximum
0.1 NTU
:)D
1 ppb
4.3 ppb
0.00005 ppm
0.003 ppm
0.090 ppm
1.2 MFI,/ml
* Tested using a flow rate of 0.5gpm (1.8927I/m); pressure of 120psi9 (8.437kg/cm2);pH of 7.5+_0.&temp. of 68%4.5°F (20°+_2.5°C)
** Measurement in particles/ml
*** NTU = Nephelometric Units
Average
99.71%
99.97%
99.37%
98.80%
91.93%
76.19%
84.89%
99.95%
Mi_num
99.59%
99.95%
99.37%
97.13%
91.93%
64.28%
67.63%
99.82%
Operating Specifications
i;i;:(:apacity: certified for up to 500 galhms (1893 1); up to one year
i_ Pressm'e requirement: 40-120 psi (2.8-8.2 bar), non-shock
N Temperature: 33°-100°F (0.6°-38°C)
_i::]_ow rate: 0.5 gI)m (1.9 lI)m )
General Installation/Operation/Maintenance Requirements
i_ Flush new cartridge at full flow for 3 minutes to i)m'ge out trai)i)ed air.
i_;:Rei)lace cartridge when flow becomes too slow.
Special Notices
i_ Installation instrttctions; parts and service availalAlity; and standard warranty are inchtded with the product when shii)i)ed.
i_;:This drinking water system must be maintained according to manufi_cturer's instructions, including rei)lacement of
filter cartridges.
>: Do not use with water that is microbiologically unsat_' or of unknown quality without adequate (lisintection before or
after the system. Systems certified tin" cyst reduction may be used on disinfected water that may contain filterable cysts.
i_;:The contaminants or other substances removed or reduced by this water treatment s}:stem are not necessarily in your water:
>: Check for compliance with the state and local laws and regulations.
Syslem Tesled mM Cerlified by NSF Int( rnational againsl ANSI/'NSF
Standard 42 & 53 tk_r tile reduction oP
Stml&ard No. 42: Aesthetic Effects
Chemical Lnit
"[-uste and Odor Reduction
Chlorine Reduction, Class I
Mechanical Fihration Lnit
Particulate Reduction, Class I
Stmldard No. 53: Health Effects
Chemical Reduction [ nit
I.ead and Atrazine Reduction
Lindane and 2,4-1) Redu(tion
Mechanical Fihration I hilt
Turbidity Reduction
Cyst and Asbestos Reduction
Manufi_ctm'ed fin': (;eneral Electric (_ompan),, I,ouisville KY 40225