Kenmore 11067902790 27-Inch Wide ELECTRIC DRYERS

Owner's Manual and Installation Instructions - Page 17

For 11067902790.

PDF File Manual, 42 pages, Read Online | Download pdf file

11067902790 photo
Loading ...
Loading ...
Loading ...
STEP 3. Attach a 3/4-inch, U.L.-listed,
strain relief to the hole below terminal
block opening. Strain relief should have
a tight fit with dryer cabinet and be in a
horizontal position. Put the power supply
cord through the strain relief.
STEP 4. Remove the center terminal
block screw. Remove the neutral ground-
ing wire (green/yellow wire) from extemal
grounding screw.
Externalground
connector
Centersilver-colored
terminalblockscrew
STEP 5. Connect neutral grounding wire
and the neutral wire (white) of power
supply cord under the center screw of
terminal block.
STEP 6. Connect the other two insulated
wires to outer terminal block screws.
STEP 7. Connect the green, grounding
wire from the power supply cord to the
external grounding conductor screw.
Tighten all terminal block screws firmly.
STEP 8. Tighten the strain relief screws.
STEP 9. Insert tab of terminal block
cover into slot of the dryer rear panel.
Secure cover with hold-down screw.
Proceed with Exhaust Installation.
See "CONNECT EXHAUST" on
page 19.
Green/yellowwire
ofharness
External
ground
connector
Centersilver-
coloredterminal
:kscrew
Whiteneutral
wire
Greenwire
ofpowersupply
cordorbare
copperwire
Neutral
groundingwire
(green/yellow)
3/ l!
/,, U.L.-listed,
strainrelief
4-Wire Connection with
Frame-Grounding Conductor
17
Loading ...
Loading ...
Loading ...