Amana TSI25VE-P1308102WE top freezer refrigerator

User Manual - Page 3

For TSI25VE-P1308102WE.

PDF File Manual, 6 pages, Download pdf file

Loading ...
Loading ...
Component Specifications
I WARNING I
To avoid risk of electrical shook, personal injury,or death, disconnect power to oven before servicing, unless
testing requires it.
Component Test Procedure
Motor, evaporator fan Volt 115 VAC, 60 Hz
Rotation (facing end opposite shatt) Clockwise
RPM 3050/3100 RPM
I/Vatt 8.3 _+15% watts
Overload, 4TM Volt 115 VAC
UIt. trip amps @ 158°F (70°C) 3.51 amps
Close temperature 142°F (61°C) _9°
Open temperature 257=F (125°C) ±.5°
Short time trip (seconds) 10 seconds -+5
Shorttimetdp(amps @770F25°C) 14amps
Relay, ptc
Illustration
10449501
10377015
10097202
3
2
_0350201
%
Resistance
With poweroffcheck:
Acrossterminals2& 3
Shorted
Open
3 - 12ohms
0 ohms
Very highor infiniteohms
Switch, single throw Type SPDT
Volt 125 VAC
Curent 4 amps
.33680308 Switch, light Type NC
Volt 125/250 VAC
Current 5/2.5 amps
10442410 Thermostat 120/'240 VAC
1000 watts
10/5 amps
Volt
Watt
Current
Resistanceacrossterminals
Above60° ± 5°F
Below37=±7°F
Between60° ±5°F and
37_± 7°F
10428601 Timer, defrost Volt
Defrost peried (minutes)
Defrost cycle (hours)
10524606 Valve, water Used on: Volt 120 VAC, 60 HZ
TSI25T Watt 20 watts
Water pressure (inlet)
Max 120 PSI
Min 20 PSI
Fill rate 137 ±15-24 CC's at 7.5 seconds
Open
Closed
Will stay in current state (either open or
closed) until either 48 ° ±5°F or 25° ±5°F is
reached,
120 VAC, 60 Hz
33 +-3.6
10
April 1999 3 RTl100035 Rev. 0