7
MAINTAIN MODE
(FLOAT MODE MONITORING)
When the CHARGED/MAINTAINING
(green) LED is pulsing, the charger has
started maintain mode. In this mode, the
charger keeps the battery fully charged
by delivering a small current when
necessary. If the charger has to provide its
maximum maintain current for a continuous
12 hour period, it will go into abort mode
(see Aborted Charge section). This is
usually caused by a drain on the battery or
the battery could be bad. Make sure there
are no loads on the battery. If there are,
remove them. If there are none, have the
battery checked or replaced.
MAINTAINING A BATTERY
The 28.71323 charges and maintains 12V
batteries, keeping them at full charge.
NOTE: The maintain mode technology
allows you to safely charge and maintain
a healthy battery for extended periods of
time. However, problems with the battery,
electrical problems in the vehicle, improper
connections or other unanticipated
conditions could cause excessive current
draws. As such, occasionally monitoring
your battery and the charging process is
required.
USING THE ENGINE START SETTING
Your battery charger can be used to jump
start your car if the battery is low. Follow
all safety instructions and precautions for
charging your battery. Wear complete eye
protection and clothing protection.
WARNING: Using the ENGINE START
setting WITHOUT a battery installed in the
vehicle will damage the vehicle’s electrical
system.
NOTE: If you have charged the battery
and it still will not start your car, do not
use the Engine Start setting, or it will
damage the vehicle’s electrical system.
Have the battery checked.
1. With the charger unplugged from the
AC outlet, connect the charger to the
battery, following the instructions given
in the CHARGING A BATTERY IN
THE VEHICLE section.
2. With the charger plugged in and
connected to the battery of the vehicle,
set the rate selection to the Engine Start
position.
3. Crank the engine until it starts or 3
seconds pass. If the engine does not
start, wait 3 minutes before cranking
again. NOTE: During extremely cold
weather, or if the battery is under 2
volts, use the 10A Boost setting for 5
minutes before cranking the engine.
4. If the engine fails to start, boost the
battery for 5 more minutes before
attempting to crank the engine again.
5. After the engine starts, unplug the AC
power cord before disconnecting the
battery clamps from the vehicle.
NOTE: If the engine does turn over but
never starts, there is not a problem with
the starting system; there is a problem
somewhere else with the vehicle. STOP
cranking the engine until the other problem
has been diagnosed and corrected.
12. MAINTENANCE AND CARE
A minimal amount of care can keep your
battery charger working properly for years.
• Clean the clamps each time you are
nished charging. Wipe off any battery
uid that may have come in contact with
the clamps to prevent corrosion.
• Occasionally cleaning the case of the
charger with a soft cloth will keep the
nish shiny and help prevent corrosion.
Coil the input and output cords neatly
when storing the charger. This will help
prevent accidental damage to the cords
and charger.
• Store the charger unplugged from the AC
power outlet in an upright position.
• Store inside, in a cool, dry place. Do not
store the clamps clipped together, on or
around metal, or clipped to the cables.