Start-up Checklist
Turn on main power to indoor and outdoor units.
Verify the system is not displaying an error code on the indoor unit display.
Point the Remote Controller at the
Floor/Ceiling unit and Press the On button.
Verify the remote controller display turns ON
and the Power Indicator lights up on the
Floor/Ceiling unit.
Press the Mode button to Cooling.
Adjust the room setpoint to bring the system on in cooling mode. The system should start
cooling mode within 3-5 minutes.
Verify the setpoint lights up on the Floor/Ceiling unit display.
Verify the outdoor fan and compressor are operating.
Verify the indoor fan is operating.
Verify the indoor discharge air is cooling the room.
Press the Mode button to Heating.
Adjust the room setpoint to bring the system on in heating mode. The system should start
heating mode within 3-5 minutes.
Verify the new setpoint lights up on the Floor/Ceiling unit display.
Verify the outdoor fan and compressor are operating.
Verify the indoor fan is operating.
Verify the indoor discharge air is heating the room.
Press the OFF button on the Remote Controller.
Verify Remote Controller display turns OFF and the system shuts OFF.
Overview of Display Panel
1. Power Indicator: Power indicator will be on after electrical power
is turned on, while it will be off after disconnecting power.
2. COOL Indicator: COOL indicator will be on after COOLmode is
activated while it will be off after COOL mode is turned off.
3. Heat Indicator: HEAT indicator will be on after HEAT mode is
activated, while it will be off after HEAT mode is turned off.
4. Indoor setpoint and temperature display.
TESTING AND INSPECTION