Base Grille Water Filtration System
Model WF-LC400V/LC400V Capacity 400 Gallons (1514 Liters)
Tosted and certified by NSF International against NSF/ANSI Standard
42 for the reduction of Chlorine, Taste and Odor, Particulate Class I*;
and against NSF/ANSI Standard 53 for the reduction of Lead,
Mercury, Atrazine, Benzene, Toxaphene, O_Dichlorobenzene,
Cysts, Turbidity, Asbestos, Lindane, Tctrachloroethylene, Endrin,
Alachtor, Chlorobenzone, Ethylbenzene, TTHM and MTBE.
This system has been tested according to ANSIiNSF 42/53 for the reduction of the substances listed beiow. The concentration of
the indicated substances in water entering the system was reduced to a concentration leas than or equaI to the permissible Iimit for
water teaving the system, as specified in ANSIiNSF 42/53.
Substance Reduction NSF Average Influent Challenge Maximum Average Minimum % Average % NSF Test
Aesthetic Effects Reduction Influent Concentration Effluent Effluent Reduction Reduction Number
Requirements
285% 2.0 mgiL_+ 10% 4,100/mL** 0.05 mg/L 07.1% 99.9% 507175-02Chlorine Taste/Odor 250% 2.1 mg/L At least 10,000 0.08 mg/L 2,3O0/mL 97.6% 507173-02
Particulate Class 1* 5,368,667/mL 99.3%
part c es/mL
Contaminant NSF Average Influent Challenge Maximum Average Minimum % Average % NSF Test
Reduction Reduction InNuent Concentration Effluent Effluent Reduction Reduction Number
Requirements
Lead: @ pH 6.5 0.OlmgiL 0.16 mg/Lt 0.15 mg/L _+10% 0.001 mg/L 0.001 mgiL 99.3% 99.35% 507601-01
Lead: @ pH 8.5 0.OlmgiL 0.15 mg/Lt 0.15 mg/L _+10% 0.001 mg/L 0.001 mgiL 99.2% 99.31% 507602-01
Mercury: @ pH 6.5 0.002 mg/L 0.0061 mg/L 0.006 mgiL = 10% 0.0004 mg/L 0.0003 mg/L 93.5% 96.7% 507603-02
Mercury: @ pH 8.5 0.002 mg/L 0.0057 mg/L 0.006 mgiL = 10% 0.0008 mg/L 0.00051 mg/L 85.8% 91.2% 507604-02
Benzene 0.005 mg/L 0.0138 mg/L 0.015_+ 10% 0.0005 mg/L 0.005 mgiL 96.3% 96.3% 507183-02
_-dichlorobenzene 0.075 mg/L 0.220 mg/L 0.225 = 10% 0.0005 mg/L 0.0005 mg/L 99.7% 99.7% 507188-02
Toxaphene 0.003 mg/L 0.014 mg/L 0.015 = 10% 0.0014 mg/L 0.00! mg/L 90% 92.96% 507185-02
Atrazine 0.003 mg/L O.0Og mgiL 0.009 mg/L ± 10% 0.0013 mg/L 0.00036 mg/L 85.6% 85.6% 507181-02
2, 4-D 0.07 mg/L 0.197 mgiL 0.215 = 10% 0.058 mg/L 0.0137 mg/L 70.6% 93.06% 507180-02
Asbestos 99% 26 x 107 1OTto 1O"fibers/Ll"l" 0.18 x 107 toga 0.18 x 107 mg/L 99.93 99.93% 507178-02
Cysts_: 99.95% 111,00O/mL 5O,0O0/L rain. 1 mg/L 1 mg/L 99.99% 99.99% 507187-02
Turbidity 0.5 NTU 11.08 NTU 11 -+1 NTU 0.13 NTU 0.078 NTU 98.8% 99.3% 507751-02
Test Parameters: pH = 7.5 ± 0.5 uniess otherwise
(t7.2°C).
It is essential that operationai, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Model WF-LO400V The filter monitor system measures the
amount of water that passes through the filter and alerts you
to repiece the filter. When 90% of the filter's rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter's rated life is used, the filter indicator light
changes from yellow to red, and it is recommended that you
replace the fitter. Use repiecement cartridge [C400V, part
#90t0. 2004 suggested retail price of $39.95 U.S.A. Prices
are subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiotogicaily unsafe or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
noted, Flow = 0.5 gpm (t.9 Lpm). Pressure = 60 psig (413.7 kPa), Temp, = 63°F
Refer to the front cover or "Accessories" section for the
Manufacturer's name, address and telephone number,
Refer to the "Warranty" section for the Manufacturer's iimited
warranty,
Application Guidelines/Water Supply Parameters
Water Supply C_ty or Wett
Water Pressure 30 - 120 psi (207 - 827 kPa)
Water Temperature 33 ° _ 100°F (0.6 ° - 37.8 ° C)
Service Flow Rate 0.5 GPM (1.89 Wmin.) @ 60 psi
F
*Class I particle size: >0.8 to <! urn
**Test requirement is at least 100,000 particles/mL of AC Fine Test Bust.
tThese contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
ttFibers greater than 10 um in length
:_Based on the use of Cryptosporidium parvum oocysts
@ NSF is a registered trademark of NSF international,