2.3 GENERAL INFORMATION
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is suitable for mobile
home installation.
No external electricity (110 volts or 24 volts) is required for the gas millivolt system operation.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be
expected.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the
appliance and shall be installed.
RATES AND EFFICIENCIES
B35 B42
NG LP NG LP
Altitude (FT) 0-4,500 0-4500 0-4,500 0-4500
Max. Input (BTU/HR) 20,000 20,000 25,000 25,000
Min. Inlet Gas Supply Pressure 4.5" (11mb) w.c. 11" (27mb) w.c. 4.5" (11mb) w.c. 11" (27mb) w.c.
Max. Inlet Gas Supply
Pressure
7" (17mb) w.c. 13" (32mb) w.c. 7" (17mb) w.c. 13" (32mb) w.c.
Manifold Pressure (Under Flow
Conditions)
3.5" (9mb) w.c. 10" (25mb) w.c. 3.5" (9mb) w.c. 10" (25mb) w.c.