6.6 BATTERY BACK-UP INSTALLATION
A. Turn the gas and electrical power off to the appliance, before beginning installation.
B. Locate the battery housing supplied in the manual baggie.
C. Install four “AA” batteries (not supplied) into the battery housing, ensure the positive and negative
ends correspond with those identi ed on the holder. (To open the battery housing, slide the back piece
upwards and off of the battery housing).
D. Remove the safety screen to easily access the control compartment.
E. Attach the wire labelled “BATTERY” from the wiring harness, located in the control compartment of the
appliance, to the battery housing.
F. Place the battery housing into the control compartment, ensure that the battery housing is placed in a
clean and easily accessible location.
G. Reinstall the safety screen. The safety screen must be installed at all times during the appliance
operation.
H. Turn the gas and electrical power back on to begin operating the appliance.
!
WARNING
ENSURE THE GAS AND ELECTRICAL POWER IS TURNED OFF TO THE APPLIANCE.
APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL THE APPLIANCE HAS COOLED.
NOTE: In the event of a power failure your appliance can be operated using the battery back-up supplied.
NOTE: Once the power has been restored remove the batteries from the holder. The system will drain
the batteries if they are left in the battery holder.