NEU MASTER N3140 600W HVLP Electric Spray Paint Gun

Installation Instructions - Page 15

For N3140.

PDF File Manual, 16 pages, Read Online | Download pdf file

N3140 photo
Loading ...
Loading ...
Loading ...
14
Closing down and cleaning
1. Turn off device. Open trigger so that the coating material in spray gun runs
back into the container.
2. Unscrew the container. Return remaining coating material into the material
can.
3. Clean the container and ascending pipe with a brush.
4. Fill the container with solvent or water.
Screw container back in place.
Only use solvent with a flash point of over 21°C
Turn on device and spray the solvent or water into a container.
If a tube is not used, some solvent or water will be deposited outside the
container.
This is due to the high air volume.
5. Repeat the above procedure until clear solvent or water comes out of the
nozzle.
6. Turn off device.
7. Then completely empty the container. Always keep the container seal free
of coating material and check for damage.
8. Clean the outside of the spray gun and container with a cloth soaked in
solvent or water.
9. Unscrew the union nut. Remove air cap .Clean the air cap and nozzle with
brush and solvent or water .
Note:
Never clean the nozzle or air hole of the spray gun with sharp metallic objects .
Troubleshooting
Problem Cause
Remedy
No coating
material is
coming out of
the
nozzle
The nozzle is blocked.
The ascending pipe is blocked.
The small hole in the ascending pipe is blocked.
Material adjustment screw turned too far to the
left (-).
Clean
Clean
Clean
Turn to the right (+)
Loading ...