GE - General Electric GN94ENSRSA01 GE water heater

User Manual - Page 2

For GN94ENSRSA01.

PDF File Manual, 6 pages, Download pdf file

Loading ...
Error codes, ge.com
Thiswater heater hasthe abilitgto check its own operation
continuouslg. If a fault occurs,an error code willflash on the
displag of the remote control onlg when the water isrunning.
Thisassistswith diagnosing the fault, and mag enable gouto
overcome a problem without a servicecall.Pleaseidentifg the
code displaged when inquiring about service.
Error Code Table
WARNING: Someof the checks below mag
need to be done bg a qualified service technician.
02 No burner operation during freeze
protection mode
10 Air supplg or exhaust blockage
11 No ignition
12 Flame failure
14 Thermal fuse
16 Over temperature warning
32-72
LC(001 Scale buildup in heat exchanger
No code Nothing happens when water flow is activated
Checkthat the gas isturned on at the water heater,gas meter or cglindeE
Ifthesgstem ispropane, make sure gas is inthe tank.
Callfor service.
EnsureGE-approvedventing materials are being used.
Checkthat nothing isblocking the flue inlet or exhaust.
Checkall vent components for proper connections.
Checkthat the gas isturned on at the water heater,gas meter or cglindeE
Ifthesgstem ispropane, make sure gas is inthe tank.
Ensureappliance is properlg grounded.
Checkthat the gas isturned on at the water heater,gas meter or cglindeE
Checkfor obstructions in the flue outlet. Ifthe sgstem ispropane, make sure
gas isin the tank.
Ensureappliance is properlg grounded.
Callfor service.
Checkfor restrictions in air flow around unit and vent outlet.
Checkfor foreign materials in exhaust piping.
Callfor service.
Seepage 11for Flushing Procedures.
Clean inletwater supplgfiltec
On new installations, ensure hot and cold water linesare not reversed.
Ensuregou have at least the minimum flow rate required to firethe unit.
9