TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
There is excessive
wobbling.
1. The blades and/or blade are
loose.
2. The blades are unbalanced.
3. The fan mounting is not secure.
4. The fan is too close to the vaulted
ceiling.
5. The set screw on the motor
housing yoke is loose.
6. The blade arms are incorrectly
attached to the blades.
1. Check and tighten all screws
that hold the fan blades to the
blade arms and the blade arms
to the motor.
2. Switch one blade with a
blade from the opposite side.
Or balance the fan using a
balancing kit (not supplied).
3. Turn off the power. Loosen
the canopy and verify that the
mounting bracket is secure to
the electrical outlet box. The
bracket must be ush without
movement against the outlet
box.
4. Use a longer downrod or move
the fan to another location.
5. Lift up the yoke cover and
tighten the set screw to the yoke
until secure.
6. Reinstall the blades to the blade
arms.
The fan operates
correctly, but
the lights are
not working (if
applicable).
1. The bulb(s) are not installed
correctly.
2. The light kit wire plugs are not
connected properly.
3. There is a faulty wire connection.
4. The total power of the light is
exceeding 190 W.
1. Re-install the bulb(s).
2. Ensure that the male and female
plugs in the light kit tter are
connected properly.
3. Turn the power off and check all
connections at the ceiling outlet
box.
4. The fan comes with a 190 W
limiter. When the total watts
of the lights is over 190 W,
the lights do not work. Please
replace the bulbs with lower-
wattage bulbs.