ASSEMBLY INSTRUCTIONS (continued) ASSEMBLY INSTRUCTIONS (continued)
A
B
SUPPLY CIRCUIT 120V
BOX
OUTLET
Fan Motor
BLUE
WHITE
WHITE
BLACK
BLUE
WHITE
BLUE
WHITE
RED
PINK
GREY
GREEN
GREEN
GREEN
WHITE
BLACK
GROUND
GROUND TO DOWNROD
GREEN
RED
PURPLE
GREY
RECEIVER
Make the following wire connections using the wire nuts supplied.
a To the household supply wires
Connect the following 4 GREEN wires to the GREEN or bare copper supply wire.
1. GREEN wire from the downrod
2. GREEN wire from the receiver
3. GREEN wire from the motor
4. GREEN wire from the mounting bracket
- Connect BLACK receiver unit wire to BLACK supply wire.
- Connect WHITE receiver unit wire to WHITE supply wire.
b To the light wires
Connect WHITE receiver wire to the WHITE wire from motor.
Connect BLUE receiver wire to the BLUE wire from motor.
c To the fan wires
Connect RED receiver wire to the RED wire from motor.
Connect GREY receiver wire to the GREY wire from motor.
Connect PINK receiver wire to the PURPLE wire from motor.
- After making the wire connections, ensure the wires should be spread
apart with the grounded conductor and the equipment-grounding
conductor on one side of the outlet box and the ungrounded conductor
on the other side of the outlet box.
- Ensure the connections after being made are turned upward and
pushed carefully up into the outlet box.
- Make sure no bare wire is visible at the wire nuts.
- Use the cable ties supplied to tighten each group of wires for easy installation.
Cable Tie
Cable Tie
Cable Tie
7. ELECTRICAL HOOK-UP
NOTE: Once ground
wires are connected,
carefully tuck all
wires and wire nuts
into the metal outlet
box making sure that
the wires are clear
of the hemisphere
and downrod when
positioned in
mounting bracket.
- Separate mounting bracket from canopy by removing screws.
- Remove cotter pin and bolt from yoke.
- Loosen the jam screws in the yoke until they are flush with the inside surface of the yoke.
- Obtain downrod, canopy and yoke cover.
- Place downrod through the canopy and yoke cover.
- Route wires exiting motor through yoke cover, canopy and downrod, insert downrod into yoke.
- Insert bolt through hole in shaft and downrod. Be careful not to damage or cut the fan wires.
- Place flat washer on the end of the bolt. Secure with cotter pin through hole
in the end of the bolt.
- Secure downrod in position by tightening jam screws. Slide yoke cover down so it is flush
with the upper cover.
5. MOUNTING
Motor
Bolt
6. INSTALL MOUNTING BRACKET
- Install J-Hook through center of outlet box and into the wooden joist.
- Attach rubber gaskets to mounting bracket and then secure to outlet box.
- Hang the safety cable from
the fan motor onto the J-hook.
Canopy
WARNING: To Reduce The Risk Of Fire, Electric Shock, Or Personal Injury, Mount
To UL/CSA Listed Outlet Box Marked Acceptable For Fan Support And Use Mounting
Screws Provided With The Outlet Box.
Yoke
Jam
Screw
Jam
Screw
Downrod
Canopy
Yoke
Cover
J-Hook
Safety
Cable
Wood
Joist
Outlet
Box
Rubber
Gasket
Mounting
Bracket
Outlet box screws
(not provided)
Ceiling
J-Hook
Bolt
Flat
Washer
Cotter Pin
Yoke
Jam
Screw
a.
b.
c.
d.
e.
PAGE: 7 / 12
PAGE: 8 / 12
ASSEMBLY INSTRUCTIONS (continued) ASSEMBLY INSTRUCTIONS (continued)
A
B
SUPP CIRCUIT 120V
BOX
OUTLET
Fan Motor
BLUE
WHITE
WHITE
BLACK
BLUE
WHITE
BLUE
WHITE
RED
PINK
GREY
GREEN
GREEN
GREEN
WHITE
BLACK
GROUND
GROUND TO DOWNROD
GREEN
RED
PURPLE
GREY
RECEIVER
-
Cable Tie
Cable Tie
Cable Tie
7. ELECTRICAL HOOK-UP
NOTE: Once ground
wires are connected,
carefully tuck all
wires and wire nuts
into the metal outlet
box making sure that
the wires are clear
of the hemisphere
and downrod when
positioned in
mounting bracket.
- Separate mounting bracket from canopy by removing screws.
- Remove cotter pin and bolt from yoke.
- Loosen the jam screws in the yoke until they are flush with the inside surface of the yoke.
- Obtain downrod, canopy and yoke cover.
- Place downrod through the canopy and yoke cover.
- Route wires exiting motor through yoke cover, canopy and downrod, insert downrod into yoke.
- Insert bolt through hole in shaft and downrod. Be careful not to damage or cut the fan wires.
- Place flat washer on the end of the bolt. Secure with cotter pin through hole
in the end of the bolt.
- Secure downrod in position by tightening jam screws. Slide yoke cover down so it is flush
with the upper cover.
5. MOUNTING
Motor
Bolt
6. INSTALL MOUNTING BRACKET
- Install J-Hook through center of outlet box and into the wooden joist.
- Attach rubber gaskets to mounting bracket and then secure to outlet box.
- Hang the safety cable from
the fan motor onto the J-hook.
Canopy
WARNING: To Reduce The Risk Of Fire, Electric Shock, Or Personal Injury, Mount
To UL/CSA Listed Outlet Box Marked Acceptable For Fan Support And Use Mounting
Screws Provided With The Outlet Box.
Yoke
Jam
Screw
Jam
Screw
Downrod
Canopy
Yoke
Cover
J-Hook
Safety
Cable
Wood
Joist
Outlet
Box
Rubber
Gasket
Mounting
Bracket
Outlet box screws
(not provided)
Ceiling
J-Hook
Bolt
Flat
Washer
Cotter Pin
Yoke
Jam
Screw
a.
b.
c.
d.
e.
Loading ...
Loading ...
Loading ...