Performance
SmartWater TM
Data Sheet o.som mo ,sJ
Filtration System-GE
MWF
Cartridge
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible
limit for water leaving the system as specified in NSF/ANSI Standard 42 and Standard 53. System tested and certified by NSF International against
NSF/ANSI Standard 42 and Standard 53 for the reduction of substances listed below.
Capacity 300 Gallons (1,135 Liters). Contaminant Reduction Determined
SubStanceTested NSFSpecified Avg_
for Reduction Average tnfluent
2.0 mg/L
Challenge Concentration
2.0 mg/L ± 10%
Reduction
97.5%
_y NSF testing.
Average Product
Water
Concentration
0.05 mg/L
At least 10,000 particles/mL
Minimum 50,000 cysts/L
107 to 108 fibers/L; fibers
greater than 10 tJm in length
0.009 mg/L + 10%
0.015 mg/L + 10%+
0.08 mg/L + 10%
0.006 mg/L + 10%
0.15 mg/L + 10%
0.15 mg/L + 10%
0.002 mg/L + 10%
0.006 mg/L + 10%
0.006 mg/L + 10%
0.225 mg/L + 10%
0.015 mg/L + 10%
0.015 mg/L + 10%
0.210 mg/L _+10%
Max Permissible
Product Water
Concentration
N/A
NSFReduction
Requirements
->50%
Test Report
J-00077703
7,833,333 pts/mL 99.7% 18,617 pts/mL N/A >85% J-00077704
101,000 cysts/L 99.99% 1 cyst/L N/A >99.95% J-00100036
>99%
94.5%
96.7%
98.7%
97.1%
99.3%
99.3%
99.0%
93.2%
93.2%
99.8%
96.7%
93.2%
99.5%
N/A
0.003 mg/L
0.005 mg/L
0.04 mg/L
0.002 mg/L
0.010 mg/L
0.010 mg/L
0.0002 mg/L
0.002 mg/L
0.002 mg/L
0.075 mg/L
0.005 mg/L
0.003 mg/L
0.07 mg/L
47 MF/L
0.009 mg/L
0.016 mg/L
0.08 rng/L
0.007 mg/L
0.152 mg/L
0.148 mg/L
0.002 mg/L
0.0058 mg/L
0.0061 mg/L
0.222 mg/L
0.015 mg/L
0.015 mg/L
0.218 mg/L
':Basedon the useof Cryptosporidium parvum oocysts.
>99%
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
<1 HF/L
0.0005 mg/L
0.0005 mg/L
0.001 mg/L
0.0002 mg/L
0.001 mg/L
0.001 mg/L
0.00002 mg/L
0.0004 mg/L
0.0004 mg/L
0.005 mg/L
0.0005 mg/L
0.001 mg/L
0.0009 mg/L
J-00077707
J-00077708
J-00077717
J-00077718
J-00100039
J-00077722
J-00077723
J-00077726
J-00100037
J-00092355
J-00077729
J-00082184
J-00077730
J-00085470
The following pharmaceutical reduction claims have not been certified by NSF International or the state of California,
Claims tested and verified by independent laboratory:
I I Average Product
Contaminant NSFspecified Avg% Water
Reduction Average tnfluent Challenge Concentration Reduction Concentration
978 ng/L N/A 99.5% 5.0 ng/L
907 ng/I N/A 99.4% 5.4 ng/L
885 ng/L N/A 94.1% 52.3 ng/L
1097 ng/L N/A 99.5% 5.0 ng/L
415 ng/L N/A 99.5% 2.0 ng/L
Max Permissible I
Product Water NSF Reduction
Concentration Requirements Test Report
N/A N/A J-00121587
N/A N/A J-00121587
N/A N/A J-00121588
N/A N/A J-00121589
N/A N/A 500121587
Application GuidelinesANater Supply Parameters
Service Flow 0.5 gpm (21.9 Ipm) Water Pressure 40-120 Ds 2 8-8 2 bar
Water Supply Potable Water Water Temperature 33°F-100°F (0.6°C-38°C)
It isessential that the manufacturer's recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.
See Installation Manual for Warranty information.
Note: While the testing was performed under standard laboratory conditions,
actual performance may vary.
Replacement Cartridge: MWR For estimated costs of replacement elements
please call 1-800-626-2002 or visit our website at www.geapplianceparts.com.
Z_WARNING
To reduce the risk associated with ingestion of contaminants:
Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before and after the system. Systems certified
for cyst reduction may be used on disinfected water that may contain filterable
cysts. EPA Establishment Number 10350-MN-005.
For conditions of use, I'/ealth claims certified by the California Department of Public
Health, and replacements, see performance data sheet. California Department
of Public Health Certification #05-1698. The contaminants or other substances
removed or reduced by this water filter are not necessarily in all users' water.
NOTICE
To reduce the risk associated with property damage due to water leakage:
Read and follow use instructions before installation and use of this system.
Installation and use MUST comply with all state and local plumbing codes.
Do not install if water pressure exceeds 120 psi (8.2 bar). If your water pressure
exceeds 80 psi, you must install a pressure-limiting valve. Contact a plumbing
professional if you are uncertain how to check your water pressure.
Do not install where water hammer conditions may occur. If water hammer
conditions exist you must install a water Iqammer arrester. Contact a plumbing
professional if you are uncertain how to check for this condition.
Do not install on hot water supply lines. The maximum operating water
temperature of this filter system is 100 ° F(38° C).
Protect filter from freezing. Drain filter when temperatures drop
below 33°F (0.6°C).
The disposebte filter cartridge must be replaced every 6 months at the
rated capacity, or sooner if a noticeable reduction in flow rate occurs.
_ Tested and certified by NSFInternational
1,_1m-£ r<_j against NSF/ANSIStandard 42 and
Standard 53 in model GEMWF fur the
REPLACEMENT_ reduction of the Uaims specified on the
ELEMENf pertotmance data sheet