After installing the appliance, wait at least 1 hour to turn on the appliance. During transportation the oil
in the compressor may have flowed into the refrigeration system.
Before switching ON the appliance for the first time, clean the interior of the appliance (see chapter
Cleaning the appliance” in the Use & Care Guide).
Electrical connection
WARNING:
These installation instructions are intended for use by qualified installers.
WARNING:
Avoid the risk of an electric shock!
Insert into a grounded receptacle.
Never remove grounding phase.
Do not use any adapters.
Do not use any extension cords.
WARNING:
It is the customer’s responsibility to ensure that the appliance installation is in compliance with all national
and local electrical codes and ordinances. Non-compliance with these instructions may result in death,
fire or an electric shock.
The receptacle must be near the appliance, 61” (1550mm) to the right of the appliance or 37” (940mm)
to the left of the appliance, and also freely accessible following installation of the appliance for future
service.
The appliance complies with protection class I. Connect the appliance to 115 V/ 60Hz alternating
current via a correctly installed receptacle with grounded terminal.
The appliance comes with a UL registered 3-wire power cord NEMA 5-15p type. The appliance
requires a 3-pole receptacle.
Never remove the grounding phase