CONNECTIONS PLUMBING
59
IN-SERIES BOOSTER
The pipe work between the solar storage tank (if one is installed) and the in-series gas booster has a
minimum recommended pipe size of DN20, MUST BE of copper and be fully insulated with a closed cell type
insulation or equivalent in accordance with the requirements of AS/NZS 3500.4.
The insulation must be weatherproof and UV resistant if exposed. The insulation must be fitted up to the
connections on both the solar storage tank and the in-series gas booster. A full flow isolation valve must be
installed on the water line to the in-series gas booster.
GAS INLET
The gas connection is made at the underside of the water heater. The pipe work must be cleared of foreign
matter before connection and purged before attempting to operate the water heater. An isolation valve and
disconnection union must be installed to allow servicing and removal of the water heater (refer to the
diagram on page 58).
Note: Refer to the Gas Installations Standard AS 5601 or AS/NZS 5601.1 for the correct method of sizing
the gas supply pipe to the water heater. The pipe size selection must take into account the high gas input of
this water heater
(refer to table on page 54) as well as all of the other gas appliances in the premises.
Warning: Always isolate the water heater before pressure testing the gas supply system. Disconnect the
water heater after the isolation valve to prevent the risk of serious damage to the gas control. The Rheem
warranty does not cover damage of any nature resulting from failure to observe this precaution. Refer to
rating label for gas types and pressures.
CONNECTIONS ELECTRICAL
All electrical work and permanent wiring must be carried out by a qualified person and in accordance with the
Wiring Rules AS/NZS 3000 and all local codes and regulatory authority requirements.
Warning: Temperature controllers must not be fitted to this water heater (874 series) if it is installed as
an in-series gas booster with a solar water heater system because water at a temperature much higher than
the controller setting can be delivered. If a solar water heater has been installed to an existing water heater
installation, then all controllers must be disconnected and removed.
The water heater is supplied with a 1.8 metre lead and plug and requires a weatherproof 240 V 50 Hz
general purpose outlet (GPO) to be located within 1.2 metres of the installation. The GPO must be clear of
the flue exhaust, draining water, gas supply pipe and water connections.
The power consumption of the water heater is:
Component
Power
consumption
Comments
Gas water heater
61 Watts
612 620, E16 Burner on, anti frost device inactive
138 Watts
612 Burner on, anti frost device active
143 Watts
616, E16 Burner on, anti frost device active
147 Watts
618 Burner on, anti frost device active
151 Watts
620 Burner on, anti frost device active
The water heater will only operate on a sine wave at 50 Hz. Devices generating a square wave cannot be
used to supply power to the water heater.