54
DIMENSIONS AND TECHNICAL DATA
Model
874 612
876 612
874 616, 874 E16
876 616, 876 E16
874 618
876 618
874 620
876 620
Rated delivery
(@ 40°C rise)
litres / min
7.5
10
11.3
12.5
Recovery
(@ 25°C rise)
litres / min
12
16
18
20
Mass Empty (unpackaged)
kg
16
16
16
16
Gas Details
Hourly Gas Consumption
(MJ)
Min. Gas
Pressure
(kPa)
Test Point Gas Pressure (kPa)
Max. Gas
Pressure
(kPa)
minimum
maximum
612
616
E16
618
620
612 to 620,
E16
612
616 to 620,
E16
612
616
E16
618
620
612 to 620,
E16
Natural
94
126
140
153
1.13
0.190
0.170
0.810
0.620
0.755
0.870
3.50
Propane
94
126
140
153
2.75
0.160
0.190
0.920
0.770
0.930
1.185
3.50
Model numbers: N = Natural, P = Propane.