Loading ...
Loading ...
Loading ...
Gas connection
1. Remove the shipping cap from gas pipe at the rear of the
dryer.
DO NOT connect the dryer to L.R gas service
without converting the gas valve. An L.R conversion kit must
be installed by a qualified gas technician.
,
Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or approved
pipe from gas supply line to the 3/8 inch (0.96 cm) pipe
located on the back of the dryer. Use a 1/2 inch to 3/8
inch (1.27 cm to 0.96 cm) reducer for the connection.
Apply an approved thread sealer that is resistant to the
corrosive action of liquefied gases on all pipe connections.
Manual GASFLOW
Shutoff Flare _ Flare
Valve Union Union
; 1 1
:losed t t
k._ Nipple Flexible Inlet Pipeon
Open Connector Back of Dryer
All connections must be wrench-tightened
The supply line must be equipped with an ap-
proved manual shutoff valve. This valve should be located in
the same room asthe dryer and should be in a location that
allows easeof opening and closing. Do not block accessto
the gas shutoff valve.
3. Open the shutoff valve in the gas supply line to allow gas
to flow through the pipe. Wait a few minutes for gas to
move through the gas line.
Shutoff Valve-
Open position
4. Check for gas system leaks with a manometer. If a
manometer is not available, test all connections by
brushing on a soapy water solution.
- EXPLOSION HAZARD - NEVERtest for gas
leaks with an open flame.
Electrical connection (non-Canada) 3-wire cord
- ELECTRICAL SHOCK HAZARD - Failure
to disconnect power source before servicing could result in
personal injury or even death.
1. Turn off power supply to outlet.
2. Remove the screw securing the terminal block access cover in the
upper corner on the back of the dryer.
3. Install a UL-approved strain relief according to the power cord/
strain relief manufacturer's instructions in the power cord entry
hole below the access panel. At this time, the strain relief should
be loosely in place.
4. Thread an UNPLUGGED,UL-approved, 30 amp. power cord,
NEMA 10-30 type SRDT,through the strain relief.
5. Attach the power cord neutral (center wire) conductor to the
SILVERcolored center terminal on the terminal block. Tighten the
screw securely.
6. Attach the remaining two power cord outer conductors to the
outer, BRASScolored terminals on the terminal block. Tighten
both screws securely.
- ELECTRICAL SHOCK HAZARD - Do not
make a sharp bend or crimp wiring/conductor at connections.
7. Follow manufacturer's guidelines for firmly securing the strain
relief and power cord.
8. Reinstall the terminal block cover.
3-wire
receptacle
(NEMA type
10-30R)
Neutral
J terminal
DO NOT remove
internal ground in a
3-wire system}
If moving dryer from a 4-wire system
and installing it in a 3-wire system, move the internal
ground from the center terminal back to the GREEN
screw next to the terminal block.
10
Loading ...
Loading ...
Loading ...